Skip to content

SparkQuote NEC calculators MCP server

ai.sparkquote/nec-calculatorssparkquote.aistreamable-httpv1.0.1Scanned

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

10 tools: 1 can delete or cancel things and 9 change things.

Tools: 1 delete, 0 irreversible, 9 write, 0 read.
  • Reads private data · 0
  • Reads text others write · 0
  • Can send data out · 0
  • 5 findings

Tools listed without sign-in. Remote posture

With Anlyon

1 tool here can delete or cancel things. Govern it.

  • Anlyon lists the tools and adopts none.
  • Each tool you adopt gets approvals and receipts.
  • Your agent never holds the key.
Govern this server →

A tool your agent calls directly is not routed through Anlyon and is not governed by it. Anlyon Radar only lists and labels, and these labels are the same either way.

What the SparkQuote NEC calculators MCP server can do

The SparkQuote NEC calculators MCP server is published by sparkquote.ai, a domain the MCP Registry verified. It has 10 tools. It can delete or cancel things (1 tool: voltage_drop) and create or change data (9 tools: wire_size, watts_to_amps, conduit_fill, box_fill and 5 more). None of its tools only reads.

None of its tools reads private data, brings in text other people write, or sends data out.

The fixed checks matched 5 findings (annotation-conflict). Each one comes with the text it matched.

Its remote endpoint lists its tools without sign-in, and its tools changed once since Anlyon Radar first saw them.

Last scanned Nov 11, 2026, version 1.0.1.

Tools

Grouped by what each tool does, most consequential first. Open one for its reasons and full description; descriptions are the publisher's own words.

10 tools

Deletes or cancels 1Claude Code: deny
  • voltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).2 findings

    Why it is in this group

    • The name "voltage_drop" says "drop": a word for removing or ending something.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    • The server marks it not destructive (destructiveHint: false), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "voltage_drop" read-only (readOnlyHint: true), and its own name, description or input give the class "destructive".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

      What this check looks for
    • Warn

      The server marks "voltage_drop" not destructive (destructiveHint: false), and its own name, description or input give the class "destructive".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

      What this check looks for
    Description, as the server wrote it
    Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

    Annotations the server declares

    • title: Voltage drop calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
Changes things 9Claude Code: ask
  • bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).

    Annotations the server declares

    • title: Electrical bid calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.1 finding

    Why it is in this group

    • The name "box_fill" says "fill": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "box_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "box_fill" says "fill": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.

    Annotations the server declares

    • title: Box fill calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.1 finding

    Why it is in this group

    • The name "conduit_fill" says "fill": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "conduit_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "conduit_fill" says "fill": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

    Annotations the server declares

    • title: Conduit fill calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minim…No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.

    Annotations the server declares

    • title: Residential load calculator (NEC 220.82)
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or …No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.

    Annotations the server declares

    • title: NEC Table 310.16 ampacity lookup
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

    Annotations the server declares

    • title: Ohm's law calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.1 finding

    Why it is in this group

    • The name "panel_schedule" says "schedule": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "panel_schedule" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "panel_schedule" says "schedule": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

    Annotations the server declares

    • title: Panel schedule generator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

    Annotations the server declares

    • title: Watts to amps calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false
  • wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table…No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.

    Annotations the server declares

    • title: Wire size calculator
    • readOnlyHint: true
    • destructiveHint: false
    • idempotentHint: true
    • openWorldHint: false

This is not a safety rating, and no finding is not a safety guarantee. The groups and findings come from fixed checks of the tool definitions the server returned on the date shown, not from its code or what it does when called. How the checks work.

Exfil surface

Which tools read private data, which read text someone else can write, and which can send data out. One of each is a path a prompt injection can use.

No private-data, untrusted-input, outbound path in this server alone: no tool is tagged private-data or untrusted-input or outbound.

Reads private data0
Reads files, mail, messages, databases, secrets, calendars or repositories.
Reads text others write0
Brings in text someone else can write: web pages, inbound email, messages, issues and comments.
Can send data out0
Can carry data to people or systems: it sends, posts or publishes, or takes a recipient, channel or URL.

Other servers in the same agent add their own tools to these paths. Audit your whole setup to see them together.

Remote posture

What anyone on the internet sees at the remote endpoint: an anonymous initialize and tools/list, and the public OAuth metadata.

Tools listed without sign-in

Looked at Nov 20, 2026, 18:27 UTC, unchanged since Oct 22, 2026. No credentials were sent and no tool was called. What is looked at.

Reachable
yes
HTTP status of an anonymous initialize
200
tools/list served without credentials
yes
Tools that change things, listed without credentials
10
Protocol version
2025-06-18
WWW-Authenticate on 401
not observed
resource_metadata in WWW-Authenticate
not observed
RFC 9728 protected resource metadata
not observed
Authorization servers
not observed
Legacy HTTP+SSE transport
no
Dynamic client registration
not observed
Client ID metadata documents
not observed
  • HighThe whole server

    The endpoint served tools/list without credentials, and the list has 10 tools that change things (1 destructive, 9 write). Whether a call also works without credentials was not tested: tools are never called.

    Matched text

    https://sparkquote.ai/mcp: tools/list returned 10 tools to an anonymous client, including voltage_drop (destructive), wire_size (write), watts_to_amps (write), conduit_fill (write), box_fill (write) and 5 more

    What this check looks for

Findings

Matches of fixed checks, with the text they matched.

5 warn
  • The server marks "voltage_drop" read-only (readOnlyHint: true), and its own name, description or input give the class "destructive".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

    What this check looks for
  • The server marks "voltage_drop" not destructive (destructiveHint: false), and its own name, description or input give the class "destructive".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "voltage_drop" says "drop": a word for removing or ending something.

    What this check looks for
  • The server marks "conduit_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "conduit_fill" says "fill": a word for a change.

    What this check looks for
  • The server marks "box_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "box_fill" says "fill": a word for a change.

    What this check looks for
  • The server marks "panel_schedule" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "panel_schedule" says "schedule": a word for a change.

    What this check looks for

History

Changes to its tool definitions and to its remote endpoint, newest first.

  1. Tools2 changed.~2 changedView diff

Install

Pinned to version 1.0.1. Values in angle brackets are yours to fill in.

claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp
claude mcp add --transport http nec-calculators https://sparkquote.ai/mcp

Run in a terminal.

Claude Code permissions

Allow the reads, ask before a change or a way out, deny the deletes. Paste into .claude/settings.json.

.claude/settings.json
{
  "permissions": {
    "allow": [],
    "ask": [
      "mcp__nec-calculators__wire_size",
      "mcp__nec-calculators__watts_to_amps",
      "mcp__nec-calculators__conduit_fill",
      "mcp__nec-calculators__box_fill",
      "mcp__nec-calculators__load_calculator",
      "mcp__nec-calculators__ohms_law",
      "mcp__nec-calculators__panel_schedule",
      "mcp__nec-calculators__bid_calculator",
      "mcp__nec-calculators__nec_ampacity"
    ],
    "deny": [
      "mcp__nec-calculators__voltage_drop"
    ]
  }
}

Tools that only read are allowed, tools that change things ask first, tools that delete or cancel are denied. A read that can send data out (it takes a URL, say) asks first too. It assumes the server is installed as nec-calculators. Review it before you use it.

Pin

Keep the decision: fail CI when the tools change, follow every change, or show a badge.

Pin in CI

Fail a build when the tools you reviewed are not the tools the server serves today.

curl -s "https://radar.anlyon.com/api/v1/servers/ai.sparkquote/nec-calculators/verify?hash=5fd656507c46e98733e12d1b563063465ea4d61c91da5103a07895022294e3b1" | jq -e '.changed == false'

Pinned hash 5fd656507c46, from Nov 11, 2026, 22:17 UTC.

Watch

Get told when its tools change: a new tool, a new description, a new class.

https://radar.anlyon.com/servers/ai.sparkquote/nec-calculators/changes.xml

An Atom feed. Works in any feed reader or Slack's RSS app.

Badge

Anlyon Radar badge for ai.sparkquote/nec-calculators
[![Anlyon Radar](https://radar.anlyon.com/badge/ai.sparkquote/nec-calculators.svg)](https://radar.anlyon.com/servers/ai.sparkquote/nec-calculators)

Source: MCP Registry. Synced Oct 21, 2026, 17:43 UTC.

SparkQuote NEC calculators MCP server: questions and answers

Answered from the scan above, not from the publisher's description.

Is the SparkQuote NEC calculators MCP server safe?

No scan can promise that. What its definitions show: 10 tools, 10 of which can change, send or delete something, and 5 findings from fixed checks. Allow the reads, ask before each change, and deny the deletes; the permissions block on this page does that.

Can the SparkQuote NEC calculators MCP server delete data?

Yes. 1 tool can delete, cancel or revoke something: voltage_drop.

Can the SparkQuote NEC calculators MCP server do things that cannot be undone?

No tool is classed as irreversible: none of them sends, pays, publishes or merges, going by their definitions.

What tools does the SparkQuote NEC calculators MCP server have?

10 tools: 1 destructive, 9 write. voltage_drop, wire_size, watts_to_amps, conduit_fill, box_fill, load_calculator, ohms_law, panel_schedule and 2 more.

Does the SparkQuote NEC calculators MCP server need sign-in or OAuth?

Its remote endpoint listed its tools to an anonymous client, without sign-in.

Does the SparkQuote NEC calculators MCP server send data to outside services?

None of its tools sends, posts or publishes, or takes a recipient, channel or URL.

Has the SparkQuote NEC calculators MCP server changed its tools?

Yes, once since Anlyon Radar started tracking it, most recently on Nov 11, 2026. Every change is on this page and in its Atom feed.