Title and description, as the publisher wrote them:

```untrusted-server-text
PlanElec Calculators
Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account.
```

Scanned 2026-11-19T20:18:07.199Z over streamable-http.

**8 tools: 4 change things and 4 only read.**

| Group | Class | Tools | Claude Code |
| --- | --- | --- | --- |
| Deletes or cancels | destructive | 0 | deny |
| Can't be undone | irreversible | 0 | ask |
| Changes things | write | 4 | ask |
| Only reads | read | 4 | allow |

## Exfil surface

No private-data -> untrusted-input -> outbound path in this server alone: no tool is tagged outbound.

| Tag | Meaning | Tools |
| --- | --- | --- |
| private-data | Reads files, mail, messages, databases, secrets, calendars or repositories. | `mcp__calculators__search_help_guides` |
| untrusted-input | Brings in text someone else can write: web pages, inbound email, messages, issues and comments. | `mcp__calculators__calculate_led_strip` `mcp__calculators__check_inverter_c10_26` `mcp__calculators__get_inverter_datasheet` `mcp__calculators__search_help_guides` `mcp__calculators__size_cable_arei` `mcp__calculators__suggest_inverter_c10_26` |
| outbound | Can carry data to people or systems: it sends, posts or publishes, or takes a recipient, channel or URL. | none |

## Findings

No check matched anything in these tool definitions.


## Changes things (4)

Creates or changes something that can be changed back. Claude Code: ask.

### `calculate_led_strip`

- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
- Tag untrusted-input: The server marks it openWorldHint: true: it reaches things outside the server's own data.

Description, as the server wrote it:

```untrusted-server-text
Calculates power, current (total and per channel), required feed points, power-supply size and the extra-low-voltage feed cable for an analogue LED strip (5/12/24/48 V DC; single colour, CCT, RGB, RGBW, RGB+CCT). Provide the strip length in metres and either a preset or the datasheet values (voltage, colour channels, watts per metre at full load). Optional: cut unit, maximum length per feed, number of feeds, power-supply reserve, feed-cable length, material and cross-section, and voltage-drop limit. Planning values from datasheet data, not a manufacturer guarantee; current-carrying capacity, heat and AREI/RGIE rules for SELV, bathrooms and outdoor areas are not checked. The response includes a shareable link that opens the calculation on planelec.be.
```

### `check_inverter_c10_26`

- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
- Tag untrusted-input: The server marks it openWorldHint: true: it reaches things outside the server's own data.

Description, as the server wrote it:

```untrusted-server-text
Checks whether a PV inverter, battery inverter or other power-generating unit (PGU) is on the Synergrid C10/26 list of devices homologated for connection to the Belgian grid. Returns the outcome (found, found_with_limitations, expired, not_found, brand), matching devices with homologation dates, limitations and firmware versions, and homologated alternatives when nothing matches. Where available, each match also carries a separate "datasheet" object with manufacturer datasheet values (DC voltage, MPPT data, links, source URLs, status, last verified date); these are NOT checked by Synergrid and are not part of the approval. Search by brand and model, for example "Huawei SUN2000-10KTL".
```

### `size_cable_arei`

- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
- Tag untrusted-input: The server marks it openWorldHint: true: it reaches things outside the server's own data.

Description, as the server wrote it:

```untrusted-server-text
Calculates the required copper or aluminium cable cross-section for a residential circuit under the Belgian AREI/RGIE: design current, voltage drop per cross-section, protection check against the breaker rating and the recommended cross-section. Provide the load (A, W, kW or kVA), one-way cable length in metres, the network (1x230V, 3x230V, 3x400V) and the breaker rating; other fields use the defaults for a typical socket circuit. The response includes a shareable link that opens the same calculation on planelec.be.
```

### `suggest_inverter_c10_26`

- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
- Tag untrusted-input: The server marks it openWorldHint: true: it reaches things outside the server's own data.

Description, as the server wrote it:

```untrusted-server-text
Typeahead for the Synergrid C10/26 list: given a partial brand or model name, returns matching brands with device counts or, once a brand is recognised, its homologated models. Use this to resolve an ambiguous device name before calling check_inverter_c10_26.
```

## Only reads (4)

Looks things up and changes nothing. Claude Code: allow.

### `get_inverter_datasheet`

- The name "get_inverter_datasheet" says "get": a word for reading.
- Tag untrusted-input: The server marks it openWorldHint: true: it reaches things outside the server's own data. The description's first sentence says "return" and "url": it reads web pages, which anyone can write.

Description, as the server wrote it:

```untrusted-server-text
Returns manufacturer datasheet data for an inverter from the Synergrid C10/26 list: maximum DC voltage, MPPT count and range, current limits per MPPT, start voltage, maximum PV power, battery capability, optimizer architecture, links to the datasheet and installation manual, the product photo URL, source URL and page per value, status (verified = stated in the datasheet, secondary = unconfirmed) and the date last verified. These are manufacturer statements and are NOT part of the Synergrid approval; use check_inverter_c10_26 for the approval status. Look up by Synergrid reference (GLV…) or by brand and model.
```

### `get_regelwerk_article`

- The name "get_regelwerk_article" says "get": a word for reading.

Description, as the server wrote it:

```untrusted-server-text
Returns the text of one article of Book 1 of the Belgian AREI/RGIE by its number (for example 4.2.4.3 or "AREI 7.1.4.3"), in the language of the text (Dutch, French or German; English uses the German text), with the edition, change notices of amending decrees, the titles of its sub-articles and a link to the article in the PlanElec reader. Cite the article number and edition when you pass the content on. Use search_regelwerk to find the number.
```

### `search_help_guides`

- The name "search_help_guides" says "search": a word for reading.
- Tag private-data: The description's first sentence says "search" and "document": it reads documents.
- Tag untrusted-input: The server marks it openWorldHint: true: it reaches things outside the server's own data.

Description, as the server wrote it:

```untrusted-server-text
Searches the PlanElec guides about getting started, automatic planning, document exports, AREI self-check coverage, floor plan import, symbols and circuits in the visitor’s current language. Returns up to five guides with title, summary, category and a link to the full article; the article text itself is not returned.
```

### `search_regelwerk`

- The name "search_regelwerk" says "search": a word for reading.

Description, as the server wrote it:

```untrusted-server-text
Searches Book 1 of the Belgian AREI/RGIE (Royal Decree on electrical installations) in the language of the text: Dutch, French or German; English uses the German text. Returns up to ten articles with number, title, an excerpt, the edition in force today and a link to the article in the PlanElec reader; the full article text is not returned, use get_regelwerk_article for it. Search by keywords or by article number such as 4.2.4.3. Results are planning aids, not an official inspection.
```

## Claude Code permissions

For `.claude/settings.json`, assuming the server is installed as `calculators`:

```json
{
  "permissions": {
    "allow": [
      "mcp__calculators__get_inverter_datasheet",
      "mcp__calculators__search_help_guides",
      "mcp__calculators__search_regelwerk",
      "mcp__calculators__get_regelwerk_article"
    ],
    "ask": [
      "mcp__calculators__check_inverter_c10_26",
      "mcp__calculators__suggest_inverter_c10_26",
      "mcp__calculators__size_cable_arei",
      "mcp__calculators__calculate_led_strip"
    ],
    "deny": []
  }
}
```

Capability tags behind the rules (a read tagged outbound is asked about):

- `mcp__calculators__check_inverter_c10_26`: untrusted-input
- `mcp__calculators__suggest_inverter_c10_26`: untrusted-input
- `mcp__calculators__get_inverter_datasheet`: untrusted-input
- `mcp__calculators__size_cable_arei`: untrusted-input
- `mcp__calculators__calculate_led_strip`: untrusted-input
- `mcp__calculators__search_help_guides`: private-data, untrusted-input

## Remote posture

What an anonymous client saw at the remote endpoint, last 2026-11-20T18:22:16.591Z, unchanged since 2026-11-06T04:18:34.327Z. No credentials were sent and no tool was called. Values are shown as the endpoint returned them. Method: https://radar.anlyon.com/methodology#remote-posture

| Fact | Observed |
| --- | --- |
| Reachable | `yes` |
| HTTP status of an anonymous initialize | `200` |
| tools/list served without credentials | `yes` |
| Tools that change things, listed without credentials | `4` |
| Protocol version | `2025-06-18` |
| WWW-Authenticate on 401 | `not observed` |
| resource_metadata in WWW-Authenticate | `none` |
| RFC 9728 protected resource metadata | `https://planelec.be/.well-known/oauth-protected-resource` |
| Authorization servers | `https://cagxtnpedoyoidditgnf.supabase.co/auth/v1` |
| Legacy HTTP+SSE transport | `no` |
| Dynamic client registration | `yes` |
| Client ID metadata documents | `no` |

- **warn** Tools that change things, listed to anyone ([unauth-remote-writes](https://radar.anlyon.com/methodology#unauth-remote-writes))

```untrusted-server-text
The endpoint served tools/list without credentials, and the list has 4 tools that change things (4 write). Whether a call also works without credentials was not tested: tools are never called.

https://planelec.be/mcp/public: tools/list returned 8 tools to an anonymous client, including check_inverter_c10_26 (write), suggest_inverter_c10_26 (write), size_cable_arei (write), calculate_led_strip (write)
```