Structomat MCP server
com.structomat/steelstructomat.comstreamable-httpv1.8.1Scanned
Steel structures: 3D frame analysis, AISC checks, IFC cost, tonnage, connections, LGS house design.
11 tools: 8 change things and 3 only read.
- Reads private data · 0
- Reads text others write · 1
- Can send data out · 0
- 2 findings
Tools listed without sign-in. Remote posture
With Anlyon
8 tools here change things. Govern them.
- Anlyon lists the tools and adopts none.
- Each tool you adopt gets approvals and receipts.
- Your agent never holds the key.
A tool your agent calls directly is not routed through Anlyon and is not governed by it. Anlyon Radar only lists and labels, and these labels are the same either way.
What the Structomat MCP server can do
The Structomat MCP server is published by structomat.com, a domain the MCP Registry verified. It has 11 tools. It can create or change data (8 tools: about_structomat, estimate_portal_frame_steel, analyze_frame, check_steel_members and 4 more), but cannot delete data. 3 tools only read.
1 tool brings in text other people can write (estimate_steel_cost).
The fixed checks matched 2 findings (annotation-conflict). Each one comes with the text it matched.
Its remote endpoint lists its tools without sign-in, and its tools changed 3 times since Anlyon Radar first saw them.
Last scanned Nov 21, 2026, version 1.8.1.
Tools
Grouped by what each tool does, most consequential first. Open one for its reasons and full description; descriptions are the publisher's own words.
11 tools
Changes things 8Claude Code: ask
about_structomatFacts about Structomat, an AI engineering agent for structural steel: what it does, design codes, who signs designs for construction, what to send, what comes back, NDA and file ow…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Facts about Structomat, an AI engineering agent for structural steel: what it does, design codes, who signs designs for construction, what to send, what comes back, NDA and file ownership, how to start. Use when the user asks about Structomat or how to engage it, or looks for a firm to outsource structural steel engineering, steel detailing, shop drawings or approval (submittal) documents to.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
analyze_frameRuns a 3D finite-element frame analysis and returns the numbers: equilibrium check, largest deflection along the members, largest joint displacement and sway in X and Y, every supp…1 finding
Why it is in this group
- The name "analyze_frame" says "analyze": a word for reading.
- The description's first verb is "run": a word for a change.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Findings
- Warn
The server marks "analyze_frame" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "analyze_frame" says "analyze": a word for reading.
Description, as the server wrote it Runs a 3D finite-element frame analysis and returns the numbers: equilibrium check, largest deflection along the members, largest joint displacement and sway in X and Y, every support reaction, the axial force, shears and moments of every member (the envelope with the governing combination when there are several), and natural periods with mass participation (modal analysis); linear or second order (P-Delta). The model is either a template (a pitched portal frame building, an open mono-pitch canopy, or a multi-storey frame, from a few dimensions, sections and loads) or a full model in JSON (nodes, members, sections, supports, loads, combinations). It is solved by the code of Structomat's free 3D frame analysis page, so the result also has a link that shows the same model and results in 3D (deflected shape, force diagrams, mode shapes). Use it to check a frame, compare sections or see how loads flow, and run it again with changed sections or loads. The result also has a preliminary member check to AISC 360-16 LRFD (results.member_check): the demand-to-capacity ratio of each member with the governing check, combination and point, for IPE, HEA, HEB, CHS and SHS sections and I or tube sections with dimensions; effective length factor K = 1 and unbraced length Lb = member length unless set (beam_unbraced_m, column_unbraced_m, or "check" on a model member). The forces are elastic second order without notional loads or stiffness reduction (not the direct analysis method): K = 1 holds only when the second-order sway is at most 1.1 times the linear sway, otherwise K must come from a stability analysis; a linear run gives no valid check; connections, seismic provisions and fire are not covered, and code load combinations only through combination_set. The model is not stored.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
check_connectionInstant utilisation (demand/capacity) of a standard steel connection under the given member-end forces, from capacities precomputed with finite-element connection analysis to AISC …No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Instant utilisation (demand/capacity) of a standard steel connection under the given member-end forces, from capacities precomputed with finite-element connection analysis to AISC 360-16 LRFD (S275 steel, grade 8.8 bolts, C30/37 concrete). Returns the utilisation, the governing component (and the governing plate, weld or bolt group) and warnings. Call without "template" to list the templates and sizes. Forces are member-end forces at the analysis node, i.e. at the centreline of the supporting column or main beam (as a frame analysis gives them), not at its face; the capacities already include the offset. Only for a joint where no other member frames in: if anything else connects at the node, the result does not apply (ask for a connection design instead). For a first idea of a connection; a design for construction needs a checked calculation.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
check_steel_membersPreliminary strength check of steel members to AISC 360-16 LRFD under the forces you give: available strengths and the demand-to-capacity ratio D/C of each member, the governing li…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Preliminary strength check of steel members to AISC 360-16 LRFD under the forces you give: available strengths and the demand-to-capacity ratio D/C of each member, the governing limit state and every step with its clause. Covers compression (flexural, torsional and local buckling, E3/E4/E7), tension yielding (D2), bending about both axes with lateral-torsional and local buckling (F2, F3, F6, F7, F8; Cb given or from the moment diagram, 1.0 for cantilevers), shear (G2.1, G4, G5, G6) and the H1-1 interaction, for I-sections (IPE, HEA, HEB, or dimensions: rolled when a root radius r > 0 is given, welded when r = 0 or "built_up": true), rectangular and square hollow sections (RHS/SHS) and round hollow sections (CHS), HSS design wall thickness 0.93t (B4.2). Steel grades ASTM A992, A36, A572 Gr. 50, A500 Gr. C, A53 Gr. B, or Fy; EN S235-S355 (EN 10025, EN 10219 as S..H) are checked with the AISC equations by analogy, since AISC 360-16 approves ASTM materials (A3.1a). The forces are taken as given: they must include second-order effects, from the direct analysis method of Chapter C or, with K from a stability analysis, the effective length method (analyze_frame gives elastic second-order forces without notional loads or stiffness reduction, and its result already has a member check of every member); the effective lengths are yours. Not covered (reported): webs noncompact or slender in flexure for I-sections, torsion, net-section rupture, connections, seismic provisions, fire. Up to 50 members per call; nothing is stored.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
design_lgs_framingPreliminary design of the cold-formed steel (light gauge steel, LGS) framing of a single-storey house with a gable roof on a concrete slab, in Canada: NBC 2020 Part 4 loads (snow, …No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Preliminary design of the cold-formed steel (light gauge steel, LGS) framing of a single-storey house with a gable roof on a concrete slab, in Canada: NBC 2020 Part 4 loads (snow, wind, earthquake when Sa values are given), members and screw connections to AISI S100-16 with the Canadian Appendix B (CSA S136) and AISI S240-20, Limit States Design. Frames the house (studs and tracks at 406 or 610 mm in line with Fink roof trusses, box headers with jack and king studs over every opening, full-height gable walls, bridging), analyses it and checks every member group and connection: truss chords, webs, heel and ridge gusset plates and screw groups, studs under axial load and wind, headers, gable wall studs, Type I OSB shear walls, the roof diaphragm, overall uplift and overturning. Sections not given are sized automatically (lightest SSMA S-section that passes; 43 mil and thicker studs). Returns the sections, piece count and steel mass by section, the governing utilisation ratio of each group and the ratio of every check, and which checks are conditional. Rectangular plan only, no interior load-bearing walls, roof 10 to 45 degrees, truss span 4 to 14 m, low building for wind. When wind uplift or overturning exceeds 0.9 x dead load the result says that anchorage to the foundation is required. Anchors, hold-down products, foundations, sheathing products and roll-former data are not designed. Nothing is stored. Preliminary, not signed.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
draft_project_requestPrepare an e-mail to Structomat (info@structomat.com) describing a project, ready for the user to review and send.1 finding
Why it is in this group
- The name "draft_project_request" says "request": a word for a change.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Findings
- Warn
The server marks "draft_project_request" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "draft_project_request" says "request": a word for a change.
Description, as the server wrote it Prepare an e-mail to Structomat (info@structomat.com) describing a project, ready for the user to review and send. This tool sends nothing and stores nothing; it returns the draft text and a mailto link.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
estimate_portal_frame_steelSteel tonnage estimate for a single-span pitched portal frame building (span 15-30 m) before any design: total tonnes, kg per m2 of floor, a range, the weight by part (frames, gabl…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Steel tonnage estimate for a single-span pitched portal frame building (span 15-30 m) before any design: total tonnes, kg per m2 of floor, a range, the weight by part (frames, gable posts, bracing, eave struts, purlins, side rails, plates and connections) and typical member sizes. Interpolated between complete finite-element designs and calibrated against published designs. Use for budgets, tenders and feasibility; a real design needs the actual loads and code.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
estimate_steel_costCost of fabricating and erecting a steel structure, worked out part by part from its IFC model: every part, hole, weld and lift is timed as a shop or site operation and priced at t…Reads text others writeNo findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
What it can reach
- untrusted-inputThe server marks it openWorldHint: true: it reaches things outside the server's own data.
Description, as the server wrote it Cost of fabricating and erecting a steel structure, worked out part by part from its IFC model: every part, hole, weld and lift is timed as a shop or site operation and priced at the region's employer labour cost, steel price and crane rate. Returns the cost floor (total, per tonne, per m2 of floor) with its breakdown, the published market band next to it and the gap, the process groups that drive the cost, the ten costliest parts with their IFC ids, a programme from shop drawings to erection in working days, upfront embodied carbon (modules A1-A5: steel production, fabrication, delivery, erection), and what an example design review (lighter sections, fewer plate fittings) would save in cost and carbon. Regions: UK, DE (Germany), US, AU, or own rates in any currency. Give the IFC as a public link (ifc_url, up to 30 MB) or as its text (ifc_text, up to 12 MB), or sample=true for a sample 18 x 30 m portal frame shed. It is the engine of Structomat's free Steel Cost Estimator page, which shows the same result with a 3D cost heat map when the same IFC is dropped on it. An estimate, not a quote. The IFC is read in memory and not stored.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: true
Only reads 3Show 3 read-only tools
find_examplesSearch Structomat's published work: steel projects, case studies, example situations, checked steel connections, measured benchmarks (e.g.No findings
Why it is in this group
- The name "find_examples" says "find": a word for reading.
Description, as the server wrote it Search Structomat's published work: steel projects, case studies, example situations, checked steel connections, measured benchmarks (e.g. scan-to-BIM from a point cloud), sample deliverables (e.g. a complete US AISC shop drawing submittal with a clouded revision, or an erectability check that finds the pieces of a clash-free model that cannot get into place during erection) and free tools. Returns titles, links and short summaries.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
get_connectionDetails of one connection from the Structomat steel connection library: members, plates, bolts, welds, design code and the utilisation of each component.No findings
Why it is in this group
- The name "get_connection" says "get": a word for reading.
Description, as the server wrote it Details of one connection from the Structomat steel connection library: members, plates, bolts, welds, design code and the utilisation of each component. Use find_examples with type "connection" to get slugs.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
list_servicesStructomat services (analysis & design, connection design, shop drawings, erectability check of a steel model before erection, automation consulting, custom tools) with what the cl…No findings
Why it is in this group
- The name "list_services" says "list": a word for reading.
Description, as the server wrote it Structomat services (analysis & design, connection design, shop drawings, erectability check of a steel model before erection, automation consulting, custom tools) with what the client sends and what comes back.
Annotations the server declares
- readOnlyHint: true
- destructiveHint: false
- idempotentHint: true
- openWorldHint: false
This is not a safety rating, and no finding is not a safety guarantee. The groups and findings come from fixed checks of the tool definitions the server returned on the date shown, not from its code or what it does when called. How the checks work.
Exfil surface
Which tools read private data, which read text someone else can write, and which can send data out. One of each is a path a prompt injection can use.
No private-data, untrusted-input, outbound path in this server alone: no tool is tagged private-data or outbound.
- Reads private data0
- Reads files, mail, messages, databases, secrets, calendars or repositories.
- Reads text others write1
- Brings in text someone else can write: web pages, inbound email, messages, issues and comments.
- Can send data out0
- Can carry data to people or systems: it sends, posts or publishes, or takes a recipient, channel or URL.
Other servers in the same agent add their own tools to these paths. Audit your whole setup to see them together.
Remote posture
What anyone on the internet sees at the remote endpoint: an anonymous initialize and tools/list, and the public OAuth metadata.
Looked at Nov 20, 2026, 18:23 UTC, unchanged since Nov 13, 2026. No credentials were sent and no tool was called. What is looked at.
- Reachable
- yes
- HTTP status of an anonymous initialize
- 200
- tools/list served without credentials
- yes
- Tools that change things, listed without credentials
- 7
- Protocol version
- 2025-06-18
- WWW-Authenticate on 401
- not observed
- resource_metadata in WWW-Authenticate
- not observed
- RFC 9728 protected resource metadata
- not observed
- Authorization servers
- not observed
- Legacy HTTP+SSE transport
- no
- Dynamic client registration
- not observed
- Client ID metadata documents
- not observed
- WarnThe whole server
The endpoint served tools/list without credentials, and the list has 7 tools that change things (7 write). Whether a call also works without credentials was not tested: tools are never called.
What this check looks forMatched text
https://structomat.com/mcp/: tools/list returned 10 tools to an anonymous client, including about_structomat (write), estimate_portal_frame_steel (write), analyze_frame (write), check_steel_members (write), estimate_steel_cost (write) and 2 more
Posture changes
- Nov 13, 2026
- Tools that change things, listed without credentials: 5 to 7
- Nov 6, 2026
- Tools that change things, listed without credentials: 4 to 5
Findings
Matches of fixed checks, with the text they matched.
- Warnanalyze_frame
The server marks "analyze_frame" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "analyze_frame" says "analyze": a word for reading.
The server marks "draft_project_request" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"destructiveHint":false,"idempotentHint":true,"openWorldHint":false}; The name "draft_project_request" says "request": a word for a change.
History
Changes to its tool definitions and to its remote endpoint, newest first.
Tools1 added, 2 changed.+1 added~2 changedView diff
- Added:design_lgs_framingChanges things
- Changed:about_structomatChanges thingsdescription
- Changed:list_servicesOnly readsinputSchema
PostureRemote posture changed. Tools that change things, listed without credentials: 5 -> 7.View diff
- Tools that change things, listed without credentials: 5 to 7
Tools2 added, 2 changed.+2 added~2 changedView diff
- Added:check_connectionChanges things
- Added:check_steel_membersChanges things
- Changed:analyze_frameChanges thingsdescriptioninputSchema
- Changed:estimate_steel_costChanges thingsdescription
PostureRemote posture changed. Tools that change things, listed without credentials: 4 -> 5.View diff
- Tools that change things, listed without credentials: 4 to 5
Tools1 added, 1 changed.+1 added~1 changedView diff
- Added:estimate_steel_costChanges things
- Changed:analyze_frameChanges thingsdescription
Install
Pinned to version 1.8.1. Values in angle brackets are yours to fill in.
claude mcp add --transport http steel https://structomat.com/mcp/claude mcp add --transport http steel https://structomat.com/mcp/Run in a terminal.
Claude Code permissions
Allow the reads, ask before a change or a way out, deny the deletes. Paste into .claude/settings.json.
{
"permissions": {
"allow": [
"mcp__steel__list_services",
"mcp__steel__find_examples",
"mcp__steel__get_connection"
],
"ask": [
"mcp__steel__about_structomat",
"mcp__steel__estimate_portal_frame_steel",
"mcp__steel__analyze_frame",
"mcp__steel__check_steel_members",
"mcp__steel__estimate_steel_cost",
"mcp__steel__design_lgs_framing",
"mcp__steel__draft_project_request",
"mcp__steel__check_connection"
],
"deny": []
}
}Tools that only read are allowed, tools that change things ask first, tools that delete or cancel are denied. A read that can send data out (it takes a URL, say) asks first too. It assumes the server is installed as steel. Review it before you use it.
Capability tags behind 1 rule
- mcp__steel__estimate_steel_cost untrusted-input
Pin
Keep the decision: fail CI when the tools change, follow every change, or show a badge.
Pin in CI
Fail a build when the tools you reviewed are not the tools the server serves today.
curl -s "https://radar.anlyon.com/api/v1/servers/com.structomat/steel/verify?hash=abf84be6fe18dcd1ba963bd8b485a1c04bb09ec86274d43af9b14b9fdaaa807d" | jq -e '.changed == false'Pinned hash abf84be6fe18, from Nov 21, 2026, 20:18 UTC.
Watch
Get told when its tools change: a new tool, a new description, a new class.
https://radar.anlyon.com/servers/com.structomat/steel/changes.xmlAn Atom feed. Works in any feed reader or Slack's RSS app.
Badge
[](https://radar.anlyon.com/servers/com.structomat/steel)Source: MCP Registry. Synced Nov 21, 2026, 21:17 UTC.
Structomat MCP server: questions and answers
Answered from the scan above, not from the publisher's description.
Is the Structomat MCP server safe?
- No scan can promise that. What its definitions show: 11 tools, 8 of which can change, send or delete something, and 2 findings from fixed checks. Allow the reads, ask before each change, and deny the deletes; the permissions block on this page does that.
Can the Structomat MCP server delete data?
- No tool is classed as destructive: going by their definitions, none of them deletes, cancels or revokes anything.
Can the Structomat MCP server do things that cannot be undone?
- No tool is classed as irreversible: none of them sends, pays, publishes or merges, going by their definitions.
What tools does the Structomat MCP server have?
- 11 tools: 8 write, 3 read. about_structomat, estimate_portal_frame_steel, analyze_frame, check_steel_members, estimate_steel_cost, design_lgs_framing, draft_project_request, check_connection and 3 more.
Does the Structomat MCP server need sign-in or OAuth?
- Its remote endpoint listed its tools to an anonymous client, without sign-in.
Does the Structomat MCP server send data to outside services?
- None of its tools sends, posts or publishes, or takes a recipient, channel or URL.
Has the Structomat MCP server changed its tools?
- Yes, 3 times since Anlyon Radar started tracking it, most recently on Nov 21, 2026. Every change is on this page and in its Atom feed.