Skip to content

Timberr Framing Tools MCP server

com.timberrframing/toolstimberrframing.comstreamable-httpv1.0.0Scanned

Planning calculators for structural framing and building projects.

14 tools: 12 change things and 2 only read.

Tools: 0 delete, 0 irreversible, 12 write, 2 read.
  • Reads private data · 2
  • Reads text others write · 0
  • Can send data out · 1
  • 2 findings

Tools listed without sign-in. Remote posture

With Anlyon

12 tools here change things. Govern them.

  • Anlyon lists the tools and adopts none.
  • Each tool you adopt gets approvals and receipts.
  • Your agent never holds the key.
Govern this server →

A tool your agent calls directly is not routed through Anlyon and is not governed by it. Anlyon Radar only lists and labels, and these labels are the same either way.

What the Timberr Framing Tools MCP server can do

The Timberr Framing Tools MCP server is published by timberrframing.com, a domain the MCP Registry verified. It has 14 tools. It can create or change data (12 tools: wall_framing_calculator, floor_joist_span_calculator, roof_rafter_span_calculator, stair_stringer_calculator and 8 more), but cannot delete data. 2 tools only read.

2 tools read private data (lintel_size_lookup and truss_vs_rafter_span_checker); 1 tool can send data out of your system (post_and_footing_size_calculator).

The fixed checks matched 2 findings (annotation-conflict). Each one comes with the text it matched.

Its remote endpoint lists its tools without sign-in.

Last scanned Nov 16, 2026, version 1.0.0.

Tools

Grouped by what each tool does, most consequential first. Open one for its reasons and full description; descriptions are the publisher's own words.

14 tools

Changes things 12Claude Code: ask
  • deck_joist_and_beam_span_calculatorMaximum deck joist span from Table 9.23.4.2.-A, the smallest built-up lumber beam from Table 9.23.4.2.-H for your post spacing, and the minimum post size from Article 9.17.4.1.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Maximum deck joist span from Table 9.23.4.2.-A, the smallest built-up lumber beam from Table 9.23.4.2.-H for your post spacing, and the minimum post size from Article 9.17.4.1. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-A and 9.23.4.2.-H, Articles 9.4.2.3., 9.4.2.2., 9.17.1.1. and 9.17.4.1., and SB-1 Table 2.

    Annotations the server declares

    • readOnlyHint: true
  • firewall_and_party_wall_fire_rating_checkerFire-resistance rating and sound rating the 2024 Ontario Building Code Part 9 requires for a wall between dwelling units: a party wall on a property line (townhouse, semi-detached)…No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Fire-resistance rating and sound rating the 2024 Ontario Building Code Part 9 requires for a wall between dwelling units: a party wall on a property line (townhouse, semi-detached), a wall between suites in one building, a house with a secondary suite, or a garage wall. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.10.8.1., 9.10.9.15., 9.10.9.16., 9.10.9.18., 9.10.11.1. to 9.10.11.4., 9.11.1.1. and 9.11.1.3., and Article 3.1.10.2. to 3.1.10.5.

    Annotations the server declares

    • readOnlyHint: true
  • floor_joist_span_calculatorMaximum floor joist span for dimension lumber from Table 9.23.4.2.-A of the 2024 Ontario Building Code, and whether your clear span is within it.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Maximum floor joist span for dimension lumber from Table 9.23.4.2.-A of the 2024 Ontario Building Code, and whether your clear span is within it. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-A, Maximum Spans for Floor Joists, General Cases.

    Annotations the server declares

    • readOnlyHint: true
  • load_bearing_wall_removal_beam_sizer_guideChecks whether removing a load-bearing wall can stay inside the Ontario Building Code Part 9 beam tables, flags when an engineer is needed, and lists the published beam size ranges…No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Checks whether removing a load-bearing wall can stay inside the Ontario Building Code Part 9 beam tables, flags when an engineer is needed, and lists the published beam size ranges from Tables 9.23.4.2.-H to -L and 9.23.4.3.-A to -J. It is not a design. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-H to -L, 9.23.4.3. and 9.23.4.3.-A to -J, Articles 9.4.1.1. and 9.23.4.1., Note A-9.23.4.2.; Building Code Act, 1992, ss. 1(1) and 8(1).

    Annotations the server declares

    • readOnlyHint: true
  • lumber_board_foot_calculatorBoard feet, linear feet and piece counts for a list of dimension lumber sizes, lengths and quantities, with a waste allowance.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Board feet, linear feet and piece counts for a list of dimension lumber sizes, lengths and quantities, with a waste allowance. Source: Board foot arithmetic on nominal size: thickness in x width in x length ft / 12; no code table involved.

    Annotations the server declares

    • readOnlyHint: true
  • nailing_schedule_lookupMinimum nail length and number or spacing of nails for framing connections, from Table 9.23.3.4.1 finding

    Why it is in this group

    • The name "nailing_schedule_lookup" says "schedule": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    Findings

    • Warn

      The server marks "nailing_schedule_lookup" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true}; The name "nailing_schedule_lookup" says "schedule": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Minimum nail length and number or spacing of nails for framing connections, from Table 9.23.3.4. of the 2024 Ontario Building Code. Filter by part of the frame and search words. Source: Ontario Building Code 2024, Division B, Table 9.23.3.4., Nailing for Framing.

    Annotations the server declares

    • readOnlyHint: true
  • post_and_footing_size_calculatorMinimum footing area and thickness for a post or column from Table 9.15.3.4.Can send data out1 finding

    Why it is in this group

    • The name "post_and_footing_size_calculator" says "post": a word for a change.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.

    What it can reach

    • outboundThe name "post_and_footing_size_calculator" says "post": it sends or publishes something to other people.

    Findings

    • Warn

      The server marks "post_and_footing_size_calculator" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

      Matched text

      annotations: {"readOnlyHint":true}; The name "post_and_footing_size_calculator" says "post": a word for a change.

      What this check looks for
    Description, as the server wrote it
    Minimum footing area and thickness for a post or column from Table 9.15.3.4. (house) or from the 2.4 kPa deck load over 75 kPa soil, the minimum post size from Article 9.17.4.1., and the minimum foundation depth from Table 9.12.2.2. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.15.1.1., 9.15.3.3. to 9.15.3.8., 9.4.2.3., 9.4.4.1. (Table 9.4.4.1.), 9.12.2.2. (Table 9.12.2.2.) and 9.17.1.1. to 9.17.4.1.

    Annotations the server declares

    • readOnlyHint: true
  • roof_pitch_rafter_length_calculatorCommon rafter length, roof angle, slope factor and plumb cut from the roof pitch, building span, overhang and ridge board thickness.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Common rafter length, roof angle, slope factor and plumb cut from the roof pitch, building span, overhang and ridge board thickness. Source: Roof geometry (Pythagorean slope factor); no code table involved.

    Annotations the server declares

    • readOnlyHint: true
  • roof_rafter_span_calculatorMaximum horizontal span of a wood roof rafter from Table 9.23.4.2.-F of the 2024 Ontario Building Code for specified roof snow loads of 1.0 to 2.0 kPa.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Maximum horizontal span of a wood roof rafter from Table 9.23.4.2.-F of the 2024 Ontario Building Code for specified roof snow loads of 1.0 to 2.0 kPa. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-F, Maximum Spans for Roof Rafters, Specified Roof Snow Loads 1.0 to 2.0 kPa.

    Annotations the server declares

    • readOnlyHint: true
  • sheathing_sheet_calculatorSheets of plywood or OSB needed to cover a floor, wall or sloped roof from its size, roof pitch, openings and waste allowance.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Sheets of plywood or OSB needed to cover a floor, wall or sloped roof from its size, roof pitch, openings and waste allowance. Source: Area arithmetic (slope factor for roofs); no code table involved.

    Annotations the server declares

    • readOnlyHint: true
  • stair_stringer_calculatorRiser count and height, treads, total run and stringer length for a straight private stair, checked against Table 9.8.4.1.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Riser count and height, treads, total run and stringer length for a straight private stair, checked against Table 9.8.4.1. of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Part 9, Table 9.8.4.1. and Articles 9.8.3.3. and 9.8.4.2.

    Annotations the server declares

    • readOnlyHint: true
  • wall_framing_calculatorStuds, plate length and plate boards for a framed wall from its length, height, stud spacing, openings, corners and intersections.No findings

    Why it is in this group

    • Nothing in its name or description says what it does, so it is counted as a write.
    • The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
    Description, as the server wrote it
    Studs, plate length and plate boards for a framed wall from its length, height, stud spacing, openings, corners and intersections. Source: Timberr Framing counting rules (field studs, king and jack studs, cripples, corners, intersections, plates); headers are not sized.

    Annotations the server declares

    • readOnlyHint: true
Only reads 2Show 2 read-only tools
  • lintel_size_lookupSmallest sawn lumber lintel over a door or window opening in a loadbearing wall, from Tables 9.23.12.3.-A to C of the 2024 Ontario Building Code.Reads private dataNo findings

    Why it is in this group

    • The name "lintel_size_lookup" says "lookup": a word for reading.

    What it can reach

    • private-dataThe description's first sentence says "table": it reads databases.
    Description, as the server wrote it
    Smallest sawn lumber lintel over a door or window opening in a loadbearing wall, from Tables 9.23.12.3.-A to C of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Tables 9.23.12.3.-A to 9.23.12.3.-C, Maximum Spans for Lintels (No. 1 or No. 2 grade lumber).

    Annotations the server declares

    • readOnlyHint: true
  • truss_vs_rafter_span_checkerReads the specified roof snow load for an Ontario city from SB-1 and Article 9.4.2.2., then checks whether a site-built rafter in Tables 9.23.4.2.-F and -G of the 2024 Ontario Buil…Reads private dataNo findings

    Why it is in this group

    • The description's first verb is "read": a word for reading.

    What it can reach

    • private-dataThe description's first sentence says "read" and "table": it reads databases.
    Description, as the server wrote it
    Reads the specified roof snow load for an Ontario city from SB-1 and Article 9.4.2.2., then checks whether a site-built rafter in Tables 9.23.4.2.-F and -G of the 2024 Ontario Building Code can span your roof or whether roof trusses are needed. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-F and 9.23.4.2.-G, Articles 9.4.2.1., 9.4.2.2. and 9.23.14.11.; SB-1 Table 2 (Ss and Sr).

    Annotations the server declares

    • readOnlyHint: true

This is not a safety rating, and no finding is not a safety guarantee. The groups and findings come from fixed checks of the tool definitions the server returned on the date shown, not from its code or what it does when called. How the checks work.

Exfil surface

Which tools read private data, which read text someone else can write, and which can send data out. One of each is a path a prompt injection can use.

No private-data, untrusted-input, outbound path in this server alone: no tool is tagged untrusted-input.

Reads private data2
Reads files, mail, messages, databases, secrets, calendars or repositories.
Reads text others write0
Brings in text someone else can write: web pages, inbound email, messages, issues and comments.
Can send data out1
Can carry data to people or systems: it sends, posts or publishes, or takes a recipient, channel or URL.

Other servers in the same agent add their own tools to these paths. Audit your whole setup to see them together.

Remote posture

What anyone on the internet sees at the remote endpoint: an anonymous initialize and tools/list, and the public OAuth metadata.

Tools listed without sign-in

Looked at Nov 17, 2026, 15:19 UTC, unchanged since Nov 17, 2026. No credentials were sent and no tool was called. What is looked at.

Reachable
yes
HTTP status of an anonymous initialize
200
tools/list served without credentials
yes
Tools that change things, listed without credentials
12
Protocol version
2025-06-18
WWW-Authenticate on 401
not observed
resource_metadata in WWW-Authenticate
not observed
RFC 9728 protected resource metadata
not observed
Authorization servers
not observed
Legacy HTTP+SSE transport
no
Dynamic client registration
not observed
Client ID metadata documents
not observed
  • WarnThe whole server

    The endpoint served tools/list without credentials, and the list has 12 tools that change things (12 write). Whether a call also works without credentials was not tested: tools are never called.

    Matched text

    https://timberrframing.com/mcp: tools/list returned 14 tools to an anonymous client, including wall_framing_calculator (write), floor_joist_span_calculator (write), roof_rafter_span_calculator (write), stair_stringer_calculator (write), roof_pitch_rafter_length_calculator (write) and 7 more

    What this check looks for

Findings

Matches of fixed checks, with the text they matched.

2 warn
  • The server marks "nailing_schedule_lookup" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true}; The name "nailing_schedule_lookup" says "schedule": a word for a change.

    What this check looks for
  • The server marks "post_and_footing_size_calculator" read-only (readOnlyHint: true), and its own name, description or input give the class "write".

    Matched text

    annotations: {"readOnlyHint":true}; The name "post_and_footing_size_calculator" says "post": a word for a change.

    What this check looks for

History

Changes to its tool definitions and to its remote endpoint, newest first.

No change seen yet. Its tools are rescanned every day, and a remote endpoint is looked at once a week.

Install

Pinned to version 1.0.0. Values in angle brackets are yours to fill in.

claude mcp add --transport http tools https://timberrframing.com/mcp
claude mcp add --transport http tools https://timberrframing.com/mcp

Run in a terminal.

Claude Code permissions

Allow the reads, ask before a change or a way out, deny the deletes. Paste into .claude/settings.json.

.claude/settings.json
{
  "permissions": {
    "allow": [
      "mcp__tools__lintel_size_lookup",
      "mcp__tools__truss_vs_rafter_span_checker"
    ],
    "ask": [
      "mcp__tools__wall_framing_calculator",
      "mcp__tools__floor_joist_span_calculator",
      "mcp__tools__roof_rafter_span_calculator",
      "mcp__tools__stair_stringer_calculator",
      "mcp__tools__roof_pitch_rafter_length_calculator",
      "mcp__tools__sheathing_sheet_calculator",
      "mcp__tools__lumber_board_foot_calculator",
      "mcp__tools__nailing_schedule_lookup",
      "mcp__tools__deck_joist_and_beam_span_calculator",
      "mcp__tools__load_bearing_wall_removal_beam_sizer_guide",
      "mcp__tools__firewall_and_party_wall_fire_rating_checker",
      "mcp__tools__post_and_footing_size_calculator"
    ],
    "deny": []
  }
}

Tools that only read are allowed, tools that change things ask first, tools that delete or cancel are denied. A read that can send data out (it takes a URL, say) asks first too. It assumes the server is installed as tools. Review it before you use it.

Capability tags behind 3 rules
  • mcp__tools__lintel_size_lookup private-data
  • mcp__tools__truss_vs_rafter_span_checker private-data
  • mcp__tools__post_and_footing_size_calculator outbound

Pin

Keep the decision: fail CI when the tools change, follow every change, or show a badge.

Pin in CI

Fail a build when the tools you reviewed are not the tools the server serves today.

curl -s "https://radar.anlyon.com/api/v1/servers/com.timberrframing/tools/verify?hash=adfe33c96317e8901c860ea63a394c92fb02a90edecf40321780b1e1bd293f40" | jq -e '.changed == false'

Pinned hash adfe33c96317, from Nov 16, 2026, 22:18 UTC.

Watch

Get told when its tools change: a new tool, a new description, a new class.

https://radar.anlyon.com/servers/com.timberrframing/tools/changes.xml

An Atom feed. Works in any feed reader or Slack's RSS app.

Badge

Anlyon Radar badge for com.timberrframing/tools
[![Anlyon Radar](https://radar.anlyon.com/badge/com.timberrframing/tools.svg)](https://radar.anlyon.com/servers/com.timberrframing/tools)

Source: MCP Registry. Synced Nov 16, 2026, 22:17 UTC.

Timberr Framing Tools MCP server: questions and answers

Answered from the scan above, not from the publisher's description.

Is the Timberr Framing Tools MCP server safe?

No scan can promise that. What its definitions show: 14 tools, 12 of which can change, send or delete something, and 2 findings from fixed checks. Allow the reads, ask before each change, and deny the deletes; the permissions block on this page does that.

Can the Timberr Framing Tools MCP server delete data?

No tool is classed as destructive: going by their definitions, none of them deletes, cancels or revokes anything.

Can the Timberr Framing Tools MCP server do things that cannot be undone?

No tool is classed as irreversible: none of them sends, pays, publishes or merges, going by their definitions.

What tools does the Timberr Framing Tools MCP server have?

14 tools: 12 write, 2 read. wall_framing_calculator, floor_joist_span_calculator, roof_rafter_span_calculator, stair_stringer_calculator, roof_pitch_rafter_length_calculator, sheathing_sheet_calculator, lumber_board_foot_calculator, nailing_schedule_lookup and 6 more.

Does the Timberr Framing Tools MCP server need sign-in or OAuth?

Its remote endpoint listed its tools to an anonymous client, without sign-in.

Does the Timberr Framing Tools MCP server send data to outside services?

1 tool can carry data out (it sends, posts or publishes, or takes a recipient, channel or URL): post_and_footing_size_calculator.

Has the Timberr Framing Tools MCP server changed its tools?

Not since Anlyon Radar started tracking it. Last scanned Nov 16, 2026.