Proven Plaza Calculators & Open Data MCP server
io.github.ZacharyVorsteg/provenplaza-agent-mcpZacharyVorstegstreamable-httpv0.1.2Scanned
29 free construction calculators plus Florida contractor, permit, federal award and AI-crawler data.
72 tools: 1 can delete or cancel things, 1 do something that can't be undone, 67 change things and 3 only read.
- Reads private data · 1
- Reads text others write · 6
- Can send data out · 6
- 6 findings
Tools listed without sign-in. Remote posture
With Anlyon
1 tool here can delete or cancel things and 1 does something that can't be undone. Govern them.
- Anlyon lists the tools and adopts none.
- Each tool you adopt gets approvals and receipts.
- Your agent never holds the key.
A tool your agent calls directly is not routed through Anlyon and is not governed by it. Anlyon Radar only lists and labels, and these labels are the same either way.
What the Proven Plaza Calculators & Open Data MCP server can do
The Proven Plaza Calculators & Open Data MCP server is published by the GitHub account ZacharyVorsteg. It has 72 tools. It can delete or cancel things (1 tool: calc_voltage_drop), do things that cannot be undone, such as sending, paying or publishing (sofl_permits) and create or change data (67 tools: calc_concrete_slab, calc_concrete_column, calc_concrete_footing, calc_paint and 63 more). 3 tools only read.
1 tool reads private data (fl_contractor_licenses); 6 tools bring in text other people can write (ai_crawler_audit, sitemap_urls, fl_contractor_licenses and 3 more); 6 tools can send data out of your system (calc_fence, ai_crawler_audit, sitemap_urls and 3 more). On its own it has all three parts of a prompt-injection exfiltration path: private data, text others write, and a way out.
The fixed checks matched 6 findings (annotation-conflict). Each one comes with the text it matched.
Its remote endpoint lists its tools without sign-in, and its tools changed once since Anlyon Radar first saw them.
Last scanned Nov 16, 2026, version 0.1.2.
Tools
Grouped by what each tool does, most consequential first. Open one for its reasons and full description; descriptions are the publisher's own words.
72 tools
Deletes or cancels 1Claude Code: deny
calc_voltage_dropVoltage drop for a single- or three-phase run using NEC Chapter 9 Table 8 conductor sizes.1 finding
Why it is in this group
- The name "calc_voltage_drop" says "drop": a word for removing or ending something.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Findings
- Warn
The server marks "calc_voltage_drop" read-only (readOnlyHint: true), and its own name, description or input give the class "destructive".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The name "calc_voltage_drop" says "drop": a word for removing or ending something.
Description, as the server wrote it Voltage drop for a single- or three-phase run using NEC Chapter 9 Table 8 conductor sizes. Formula: VD = 2 × K × I × L ÷ CM (single phase) or √3 × K × I × L ÷ CM (three phase); K = ohm·cmil/ft (approx. 12.9 Cu, 21.2 Al); CM from NEC Ch. 9 Table 8.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
Can't be undone 1Claude Code: ask
sofl_permitsRecent building permits from Miami-Dade County and Fort Lauderdale open data, filterable by date and keyword.Reads text others writeCan send data out1 finding
Why it is in this group
- The input addresses people (input.to): what it sends cannot be taken back.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
What it can reach
- untrusted-inputThe server marks it openWorldHint: true: it reaches things outside the server's own data.
- outboundThe input takes a destination (input.to): what the tool writes goes there.
Findings
- Warn
The server marks "sofl_permits" read-only (readOnlyHint: true), and its own name, description or input give the class "irreversible".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":true}; The input addresses people (input.to): what it sends cannot be taken back.
Description, as the server wrote it Recent building permits from Miami-Dade County and Fort Lauderdale open data, filterable by date and keyword. Owner names excluded.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: true
Changes things 67Claude Code: ask
agent_readiness_scoreFree 0-100 score of how easily AI assistants and agents can read, quote and contact a public business website: AI crawler rules, llms.txt, schema.org business/offer data, agent cat…Reads text others writeCan send data outNo findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
What it can reach
- untrusted-inputThe server marks it openWorldHint: true: it reaches things outside the server's own data.
- outboundThe input takes a URL (input.url): a request to a URL can carry data to whoever runs it.
Description, as the server wrote it Free 0-100 score of how easily AI assistants and agents can read, quote and contact a public business website: AI crawler rules, llms.txt, schema.org business/offer data, agent catalog, MCP card, sitemap, meta, contact. Not a Google ranking score.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: true
agent_ready_fix_packGenerate robots.txt AI-crawler rules, llms.txt, schema.org JSON-LD and /.well-known/agent-catalog.json from facts the business supplies.Can send data out1 finding
Why it is in this group
- The description's first verb is "generate": a word for a change.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
What it can reach
- outboundThe input takes a destination (input.phone): what the tool writes goes there.
- outboundThe input takes a URL (input.url): a request to a URL can carry data to whoever runs it.
Findings
- Warn
The server marks "agent_ready_fix_pack" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The description's first verb is "generate": a word for a change.
Description, as the server wrote it Generate robots.txt AI-crawler rules, llms.txt, schema.org JSON-LD and /.well-known/agent-catalog.json from facts the business supplies. services: one per line as "Name|Price". Uses only supplied facts.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
ai_crawler_auditCheck a public site robots.txt for AI crawler allow/deny verdicts.Reads text others writeCan send data outNo findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
What it can reach
- untrusted-inputThe server marks it openWorldHint: true: it reaches things outside the server's own data.
- outboundThe input takes a URL (input.url): a request to a URL can carry data to whoever runs it.
Description, as the server wrote it Check a public site robots.txt for AI crawler allow/deny verdicts.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: true
calc_ac_btuRoom air-conditioner capacity using the ENERGY STAR sizing chart and its adjustments for sun, occupants and kitchens.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Room air-conditioner capacity using the ENERGY STAR sizing chart and its adjustments for sun, occupants and kitchens. Formula: Base BTU from the ENERGY STAR area chart; −10% heavily shaded, +10% very sunny, +600 BTU per person above 2, +4,000 BTU for a kitchen.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_appliance_energy_costDaily and yearly kWh and the cost to run any appliance from its wattage, hours of use and your electricity rate.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Daily and yearly kWh and the cost to run any appliance from its wattage, hours of use and your electricity rate. Formula: kWh per day = watts × hours ÷ 1,000; kWh per year = kWh per day × days; cost = kWh × rate.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_asphaltTons of hot-mix asphalt for a driveway or lot from area, compacted depth and mix density.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Tons of hot-mix asphalt for a driveway or lot from area, compacted depth and mix density. Formula: Tons = L × W × depth(in)/12 × density(lb/cu ft) ÷ 2,000.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_attic_ventilationHow much attic ventilation you need by the 1/150 and 1/300 rules (Florida Building Code, Residential R806.2), split into intake and exhaust, and how many vents that is for your ven…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much attic ventilation you need by the 1/150 and 1/300 rules (Florida Building Code, Residential R806.2), split into intake and exhaust, and how many vents that is for your vent products. Formula: Total net free area (sq in) = attic floor area (sq ft) × 144 ÷ 150 (or ÷ 300 under the balanced exception). Exhaust NFA = total × high share; intake NFA = the rest. Vents = ⌈NFA ÷ the net free area of one vent (or one foot of continuous vent)⌉.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_board_footBoard feet and cost for hardwood or dimensional lumber.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Board feet and cost for hardwood or dimensional lumber. Formula: Board feet = thickness(in) × width(in) × length(ft) ÷ 12 × pieces (one board foot = 144 cubic inches).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_box_fillRequired box volume under NEC 314.16 from your conductors, devices, clamps, fittings and grounds, checked against a standard metal box from Table 314.16(A) or your box's marked vol…1 finding
Why it is in this group
- The name "calc_box_fill" says "fill": a word for a change.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Findings
- Warn
The server marks "calc_box_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The name "calc_box_fill" says "fill": a word for a change.
Description, as the server wrote it Required box volume under NEC 314.16 from your conductors, devices, clamps, fittings and grounds, checked against a standard metal box from Table 314.16(A) or your box's marked volume. Formula: Required volume = Σ(conductors × Table 314.16(B) allowance) + 1 allowance for clamps + 1 per fitting type + 2 per yoke + 1 for all grounds, each at the largest conductor size present. Allowances: 18 AWG 1.50, 16 AWG 1.75, 14 AWG 2.00, 12 AWG 2.25, 10 AWG 2.50, 8 AWG 3.00, 6 AWG 5.00 cu in.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_brickBricks for a single-wythe wall from its area, the brick face size and the mortar joint.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Bricks for a single-wythe wall from its area, the brick face size and the mortar joint. Defaults are a modular brick with a ⅜ in joint. Formula: Bricks per sq ft = 144 ÷ ((length + joint) × (height + joint)); bricks = (wall area − openings) × bricks per sq ft × (1 + waste%).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_caulkHow many tubes of caulk or sealant to buy: linear feet per cartridge for your joint width and depth (or a triangular corner bead), and cartridges for the total length.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How many tubes of caulk or sealant to buy: linear feet per cartridge for your joint width and depth (or a triangular corner bead), and cartridges for the total length. Formula: Cartridge volume = fl oz × 1.80469 cu in. Bead area = width × depth (or leg² ÷ 2). Linear feet per cartridge = volume ÷ (bead area × 12). Cartridges = length × (1 + waste) ÷ feet per cartridge.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_ceiling_fan_sizeWhat size ceiling fan you need for a room: the suggested blade span from the room's square footage, the largest fan that keeps 18 in from the walls, and the mount type for your cei…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it What size ceiling fan you need for a room: the suggested blade span from the room's square footage, the largest fan that keeps 18 in from the walls, and the mount type for your ceiling height. Formula: Area = length × width. Blade span: up to 75 sq ft 29–36 in; 76–144 sq ft 36–42 in; 144–225 sq ft 44 in; 225–400 sq ft 50–54 in; over 400 sq ft 54–72 in or several fans. Largest span with 18 in wall clearance = shorter side (in) − 36 in. Mount: 8 ft or lower → hugger; 8–9 ft → standard downrod; higher → extended downrod.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_concrete_blockNumber of 8×8×16 concrete blocks (CMU) for a wall.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Number of 8×8×16 concrete blocks (CMU) for a wall. A standard block plus a ⅜ in joint covers 16 × 8 in, so about 1.125 blocks per square foot. Formula: Blocks per sq ft = 144 ÷ ((length + joint) × (height + joint)) = 144 ÷ (16 × 8) = 1.125 for standard units; blocks = net wall area × 1.125 × (1 + waste%).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_concrete_columnConcrete needed for round columns, piers and tube forms (sonotubes).No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Concrete needed for round columns, piers and tube forms (sonotubes). Uses cylinder volume, which differs from slab math. Formula: Cubic feet = π × (diameter(in)/24)² × height(ft) × count; cubic yards = cu ft ÷ 27 × (1 + waste%).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_concrete_footingVolume for continuous trench/wall footings where width is in inches and length runs the full perimeter.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Volume for continuous trench/wall footings where width is in inches and length runs the full perimeter. Formula: Cubic yards = Length(ft) × Width(in)/12 × Depth(in)/12 ÷ 27 × (1 + waste%).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_concrete_slabEstimate ready-mix cubic yards or the number of 80 lb bags for a rectangular slab, patio or driveway.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Estimate ready-mix cubic yards or the number of 80 lb bags for a rectangular slab, patio or driveway. Formula: Cubic yards = Length(ft) × Width(ft) × Thickness(in)/12 ÷ 27 × (1 + waste%). Bags = cubic feet ÷ bag yield.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_concrete_stepsHow much concrete solid steps need, from the total height to climb: number of risers, riser height, treads, top landing, cubic yards and 80 lb bags.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much concrete solid steps need, from the total height to climb: number of risers, riser height, treads, top landing, cubic yards and 80 lb bags. Formula: Risers n = ⌈total rise ÷ max riser⌉; riser height R = total rise ÷ n. Side profile area = tread × R × n(n − 1) ÷ 2 + landing depth × n × R (each lower tread is a block of its own height; the landing sits at full height). Volume (cu ft) = profile (sq in) × width (in) ÷ 1,728; cubic yards = cu ft × (1 + waste) ÷ 27; bags = cu ft × (1 + waste) ÷ bag yield.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_conduit_fillConduit fill for THHN/THWN-2 wires in EMT or Schedule 40 PVC: total wire area, percent fill against the NEC 53/31/40% limits, whether it fits, the smallest conduit that does, and t…1 finding
Why it is in this group
- The name "calc_conduit_fill" says "fill": a word for a change.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Findings
- Warn
The server marks "calc_conduit_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The name "calc_conduit_fill" says "fill": a word for a change.
Description, as the server wrote it Conduit fill for THHN/THWN-2 wires in EMT or Schedule 40 PVC: total wire area, percent fill against the NEC 53/31/40% limits, whether it fits, the smallest conduit that does, and the maximum number of same-size wires. Formula: Wire area = Σ count × Table 5 area (14 AWG 0.0097, 12 AWG 0.0133, 10 AWG 0.0211, 8 AWG 0.0366, 6 AWG 0.0507 sq in …). Allowed = Table 4 conduit area × 53% (1 wire), 31% (2) or 40% (3+). Same-size maximum = allowed ÷ wire area, rounded up only at 0.8 or more.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_deck_boardNumber of deck boards for a rectangular deck, accounting for board width and gap.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Number of deck boards for a rectangular deck, accounting for board width and gap. Formula: Rows = ⌈width(in) ÷ (board width + gap)⌉; boards = rows × ⌈deck length ÷ board length⌉ × (1 + waste%).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_dehumidifier_sizeWhat size portable dehumidifier you need, in pints per day, from the ENERGY STAR chart for your space size and how damp it is, with a liters and gallons conversion.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it What size portable dehumidifier you need, in pints per day, from the ENERGY STAR chart for your space size and how damp it is, with a liters and gallons conversion. Formula: Pick the ENERGY STAR range for the condition and size (under or over 2,000 sq ft), then take the top of the range, or the water your current unit removes per day if that is higher. Liters = pints × 0.4732; gallons = pints ÷ 8.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_drywallNumber of drywall sheets for walls and optionally the ceiling.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Number of drywall sheets for walls and optionally the ceiling. Formula: Sheets = (perimeter × height + ceiling area) × (1 + waste%) ÷ sheet area.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_epoxy_floorHow much epoxy floor coating to buy: coverage per gallon at your dry film thickness and volume solids, gallons per coat, total with losses, and kits.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much epoxy floor coating to buy: coverage per gallon at your dry film thickness and volume solids, gallons per coat, total with losses, and kits. Formula: Coverage (sq ft/gal) = 1,604 × solids by volume ÷ dry mils. Gallons per coat = area ÷ coverage. Total = gallons per coat × coats × (1 + loss). Wet mils = dry mils ÷ solids.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_ev_charging_costWhat it costs to charge an electric car at home: cost per mile, per month and per full charge from your car's kWh per 100 miles and your state's average residential electricity pri…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it What it costs to charge an electric car at home: cost per mile, per month and per full charge from your car's kWh per 100 miles and your state's average residential electricity price (EIA, August 2026) or your own rate, with an optional gas comparison. Formula: Cost per mile = kWh/100 mi ÷ 100 × $/kWh ÷ (1 − loss%). Month = cost per mile × miles. Full charge = battery kWh × $/kWh ÷ (1 − loss%). Gas cost per mile = $/gal ÷ mpg.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_fencePosts, rails and pickets for a straight run of wood privacy or picket fence.Can send data out1 finding
Why it is in this group
- The description's first verb is "post": a word for a change.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
What it can reach
- outboundThe description's first verb is "post": it sends or publishes something to other people.
Findings
- Warn
The server marks "calc_fence" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The description's first verb is "post": a word for a change.
Description, as the server wrote it Posts, rails and pickets for a straight run of wood privacy or picket fence. Formula: Sections = ⌈length ÷ spacing⌉; posts = sections + 1 + gates; pickets = ⌈length(in) ÷ (picket width + gap)⌉.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_flooring_tileSquare footage plus waste and number of boxes for tile, laminate, vinyl plank or hardwood.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Square footage plus waste and number of boxes for tile, laminate, vinyl plank or hardwood. Formula: Area = L × W; to buy = area × (1 + waste%); boxes = to buy ÷ coverage per box.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_generator_sizeWhat size generator you need for a power outage: add the running watts of everything you will run at once, then add the single biggest motor starting surge.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it What size generator you need for a power outage: add the running watts of everything you will run at once, then add the single biggest motor starting surge. Enter how many of each item you plan to run at the same time. Formula: Total running watts = Σ (quantity × running watts). Total starting watts = total running watts + the single highest additional starting watts among the items you run, because motors rarely start at the same instant. Amps at 240 V = running watts ÷ 240. Margin is an optional buffer you choose.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_grass_seedHow much grass seed to buy for a new lawn: university seeding rates per 1,000 sq ft for each grass type or mix, adjusted for the purity and germination printed on the seed tag.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much grass seed to buy for a new lawn: university seeding rates per 1,000 sq ft for each grass type or mix, adjusted for the purity and germination printed on the seed tag. Formula: Pure live seed (PLS) = purity × germination. Seed (lb) = rate (lb PLS per 1,000 sq ft) × area ÷ 1,000 ÷ PLS. Bags = high-rate pounds ÷ bag size, rounded up.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_groutHow much grout a tile job takes from the tile size, joint width, joint depth and area, in pounds and bags.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much grout a tile job takes from the tile size, joint width, joint depth and area, in pounds and bags. The grout density is editable so you can match your product. Formula: Each tile plus its joint is a (L + J) × (W + J) module, of which J × (L + W + J) is joint. Joint share = J(L + W + J) ÷ ((L + J)(W + J)). Grout volume (cu ft) = area × joint share × depth(in) ÷ 12; pounds = volume × density × (1 + waste); bags = ⌈pounds ÷ bag size⌉.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_gutter_sizeCheck whether a gutter can carry the runoff from your roof in a design storm, and how many downspouts it needs.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Check whether a gutter can carry the runoff from your roof in a design storm, and how many downspouts it needs. Uses the USDA NRCS gutter and downspout capacity table and your local rainfall intensity. Formula: Runoff Q (cfs) = roof area (sq ft) × rainfall intensity (in/hr) ÷ 43,200 (12 in/ft × 3,600 s/hr); gpm = cfs × 448.8. The gutter is adequate when Q ≤ its NRCS PA-1 capacity at your slope. Downspouts = the larger of ⌈Q ÷ one downspout's PA-1 capacity⌉ and ⌈run length ÷ max length per downspout⌉. Max roof area for the gutter = capacity × 43,200 ÷ intensity.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_insulation_r_valueThickness needed to reach a target R-value for the R-per-inch printed on your insulation product.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Thickness needed to reach a target R-value for the R-per-inch printed on your insulation product. Formula: Thickness(in) = target R ÷ R per inch. Volume in board feet = area(sq ft) × thickness(in).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_joint_compoundHow much drywall mud and tape to buy: gallons of ready-mix joint compound, 4.5 gal pails and rolls of paper tape for your square footage of drywall, using USG's published coverage.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much drywall mud and tape to buy: gallons of ready-mix joint compound, 4.5 gal pails and rolls of paper tape for your square footage of drywall, using USG's published coverage. Formula: Gallons = area × coverage ÷ 1,000 × (1 + waste). Pails = gallons ÷ pail size, rounded up. Tape (ft) = area × 370 ÷ 1,000 × (1 + waste). Rolls = tape ÷ roll length, rounded up.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_lawn_fertilizerHow much fertilizer to put on your lawn: pounds of product per 1,000 sq ft and for the whole lawn, from the nitrogen rate you want and the N-P-K numbers on the bag, plus bags to bu…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much fertilizer to put on your lawn: pounds of product per 1,000 sq ft and for the whole lawn, from the nitrogen rate you want and the N-P-K numbers on the bag, plus bags to buy and the phosphate and potash you apply along with it. Formula: Product per 1,000 sq ft = N rate ÷ (N% ÷ 100). Total = product per 1,000 × area ÷ 1,000. Bags = total ÷ bag weight, rounded up. P₂O₅ (or K₂O) per 1,000 = product per 1,000 × P% (or K%) ÷ 100.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_mortarMortar for a brick or concrete block wall: units needed, cubic feet of mortar from the Brick Industry Association quantity table (with bond-pattern correction and waste) and bags o…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Mortar for a brick or concrete block wall: units needed, cubic feet of mortar from the Brick Industry Association quantity table (with bond-pattern correction and waste) and bags of mason mix. Formula: Brick = wall ÷ 100 × Table 4 brick per 100 sq ft × (1 + bond brick factor). Mortar (cu ft) = brick ÷ 1,000 × Table 4 cu ft per 1,000 brick for the joint × (1 + bond mortar factor) × (1 + waste). Block = wall × 1.125. Bags = units ÷ units per bag × (1 + waste).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_mulch_gravelCubic yards (and optional tons) of mulch, gravel, sand or soil for a bed or path.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Cubic yards (and optional tons) of mulch, gravel, sand or soil for a bed or path. Formula: Cubic yards = L(ft) × W(ft) × depth(in) ÷ 324 (since 27 cu ft × 12 in = 324). Tons = cu yd × supplier density.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_oval_pool_volumeGallons in an oval (elliptical) pool.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Gallons in an oval (elliptical) pool. Formula: Gallons = π × (L/2) × (W/2) × average depth × 7.48052.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_paintGallons of wall paint from room perimeter and height, minus doors and windows, for any number of coats.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Gallons of wall paint from room perimeter and height, minus doors and windows, for any number of coats. Formula: Paintable area = perimeter × height − 20 sq ft per door − 15 sq ft per window. Gallons = area × coats ÷ label coverage.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_paverNumber of pavers for a patio, walkway or driveway plus cubic yards of compacted base and bedding sand.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Number of pavers for a patio, walkway or driveway plus cubic yards of compacted base and bedding sand. Formula: Pavers per sq ft = 144 ÷ (paver length × width); pavers = area × per sq ft × (1 + waste%). Base and sand cubic yards = area × depth(in) ÷ 324.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_alkalinityHow much baking soda raises your pool's total alkalinity, or how much muriatic acid or dry acid lowers it, for your pool size, using published doses per 10,000 gallons.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much baking soda raises your pool's total alkalinity, or how much muriatic acid or dry acid lowers it, for your pool size, using published doses per 10,000 gallons. Formula: Batches = |target − current| ÷ 10 × gallons ÷ 10,000. Raise: baking soda (lb) = batches × 1.4. Lower: muriatic acid 31.4% (fl oz) = batches × 26, or sodium bisulfate (lb) = batches × 2.1. Additions: raise no more than about 50 ppm at a time; add no more than 1 quart of acid per 10,000 gallons at a time.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_calcium_hardnessHow much calcium chloride raises your pool's calcium hardness, or how much water to replace to lower it, based on your pool size and fill-water hardness.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much calcium chloride raises your pool's calcium hardness, or how much water to replace to lower it, based on your pool size and fill-water hardness. Formula: Raise: calcium chloride (lb) = (target − current) ÷ 10 × gallons ÷ 10,000 × 1.2 for 77% (0.9 for 100%). Lower (dilution): share to drain = (current − target) ÷ (current − fill water); gallons = share × pool volume.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_chlorineFluid ounces of liquid chlorine (sodium hypochlorite) to raise free chlorine by a target number of ppm, from pool volume and product strength.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Fluid ounces of liquid chlorine (sodium hypochlorite) to raise free chlorine by a target number of ppm, from pool volume and product strength. Formula: Available chlorine (g) = gallons × 3.78541 L/gal × ppm (mg/L) ÷ 1,000. Product (mL) = grams ÷ (strength% ÷ 100), since trade percent is grams of available chlorine per 100 mL. Fl oz = mL ÷ 29.5735.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_heater_sizeHeater output in Btu per hour for an outdoor pool from surface area and temperature rise, using the U.S.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Heater output in Btu per hour for an outdoor pool from surface area and temperature rise, using the U.S. Department of Energy formula, plus gas input, the matching standard heat pump size and the time to warm the water. Formula: Temperature rise = desired pool temperature − average air temperature of the coldest month of use. Heater output (Btu/h) = surface area × rise × 12 × rate factor (1, 1.5 or 2). Gas input = output ÷ efficiency. Heat to warm the water once = gallons × 8.34 lb × (desired − starting temperature); hours = that ÷ output, with no losses.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_lsiLangelier Saturation Index for your pool or spa from pH, water temperature, calcium hardness and total alkalinity, using the factor table and formula in state pool rules, plus the …No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Langelier Saturation Index for your pool or spa from pH, water temperature, calcium hardness and total alkalinity, using the factor table and formula in state pool rules, plus the pH that would balance it. Formula: SI = pH + TF + CF + AF − 12.1 (12.2 when TDS is above 1,000 ppm). TF, CF and AF come from the temperature, calcium hardness and alkalinity factor table; when a reading falls between rows the table method uses the next greater row. pH for SI = 0: 12.1 − TF − CF − AF.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_saltPounds and bags of pool salt to raise a saltwater pool from its current salt level to the target your chlorine generator needs.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Pounds and bags of pool salt to raise a saltwater pool from its current salt level to the target your chlorine generator needs. Formula: Salt (lb) = gallons × 8.34 lb/gal × (target ppm − current ppm) ÷ 1,000,000. Bags = ⌈lb ÷ bag size⌉.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_stabilizerHow much stabilizer (cyanuric acid, CYA) raises your pool to a target level, or how much water to drain and refill to lower it.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much stabilizer (cyanuric acid, CYA) raises your pool to a target level, or how much water to drain and refill to lower it. Formula: Raise: stabilizer (oz) = (target − current) ÷ 10 × gallons ÷ 10,000 × 13. Lower (dilution): share to drain = (current − target) ÷ (current − fill water); gallons = share × pool volume.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_turnoverThe flow rate (gpm) your pool pump must deliver for a target turnover time, your actual turnover from a flow meter reading, and whether your filter is big enough for that flow.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it The flow rate (gpm) your pool pump must deliver for a target turnover time, your actual turnover from a flow meter reading, and whether your filter is big enough for that flow. Formula: Required flow (gpm) = gallons ÷ (turnover hours × 60). Actual turnover (hours) = gallons ÷ (measured gpm × 60). Filter max flow = filter area × rated gpm per sq ft.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_pool_volumeGallons in a rectangular pool with a sloped bottom, using average depth.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Gallons in a rectangular pool with a sloped bottom, using average depth. Formula: Gallons = L × W × (shallow + deep)/2 × 7.48052 gal/cu ft.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_rafter_lengthCommon rafter length, ridge rise and roof angle from the horizontal run and pitch, with optional overhang.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Common rafter length, ridge rise and roof angle from the horizontal run and pitch, with optional overhang. Formula: Pitch factor = √(1 + (rise/12)²). Rafter length = (run + overhang) × pitch factor. Ridge rise = run × rise ÷ 12. Angle = atan(rise ÷ 12).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_rainwater_harvestingHow many gallons of rainwater your roof can collect from a storm, a month or a year of rain, how many rain barrels that fills, and how much to divert as first flush, using the Texa…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How many gallons of rainwater your roof can collect from a storm, a month or a year of rain, how many rain barrels that fills, and how much to divert as first flush, using the Texas Manual on Rainwater Harvesting method. Formula: Gallons = rainfall (in) × roof footprint (sq ft) × 0.62 × efficiency. Barrels = gallons ÷ barrel size, rounded up. First flush = roof ÷ 1,000 × 10 gal.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_rebarHow much rebar a rectangular slab grid needs: bar count each way, lap splices, total linear feet, 20 ft sticks to order and steel weight from ASTM A615 bar weights.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How much rebar a rectangular slab grid needs: bar count each way, lap splices, total linear feet, 20 ft sticks to order and steel weight from ASTM A615 bar weights. Formula: Bars each way = ⌊(clear span ÷ spacing)⌋ + 1, where clear span = side × 12 − 2 × edge clearance. A run longer than one stick needs ⌈(run − lap) ÷ (stick − lap)⌉ pieces, adding one lap per joint; lap = bar diameters × bar diameter. Linear ft = (bars × run + splices × lap) ÷ 12; sticks = ⌈linear ft × (1 + allowance) ÷ stick length⌉; weight = linear ft × ASTM A615 lb/ft.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_retaining_wallHow many retaining wall blocks you need for a straight wall or a circle (fire pit, tree ring), including the buried course, cap units, base gravel for the leveling pad and drainage…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How many retaining wall blocks you need for a straight wall or a circle (fire pit, tree ring), including the buried course, cap units, base gravel for the leveling pad and drainage rock behind the wall. Block sizes are editable because every product line differs. Formula: Buried depth = max(exposed height ÷ bury ratio, minimum). Courses = ⌈(exposed height + buried depth − cap height) ÷ block height⌉. Blocks per course = ⌈run ÷ block face length⌉, where run = wall length, or π × outside diameter for a circle. Wall blocks = ⌈blocks per course × courses × (1 + waste%)⌉; caps = ⌈run ÷ cap length × (1 + waste%)⌉. Base gravel cu yd = run(ft) × trench width(in) × base depth(in) ÷ 144 ÷ 27; drainage rock cu yd = run(ft) × zone depth(in) × stacked block height(in) ÷ 144 ÷ 27 (straight walls only).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_roofingRoof area from the house footprint and pitch, converted to roofing squares (100 sq ft) and shingle bundles.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Roof area from the house footprint and pitch, converted to roofing squares (100 sq ft) and shingle bundles. Formula: Pitch factor = √(1 + (rise/12)²). Roof area = (L + 2×overhang) × (W + 2×overhang) × pitch factor. Squares = area ÷ 100 × (1 + waste%).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_round_pool_volumeGallons in a round or above-ground pool.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Gallons in a round or above-ground pool. Formula: Gallons = π × (D/2)² × average depth × 7.48052 (≈ D² × depth × 5.875).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_self_leveling_concreteHow many bags of self-leveling underlayment or floor resurfacer to buy, from your floor area and the thinnest and thickest pour depth, using the bag's yield in cubic feet.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How many bags of self-leveling underlayment or floor resurfacer to buy, from your floor area and the thinnest and thickest pour depth, using the bag's yield in cubic feet. Formula: Average depth = (thinnest + thickest) ÷ 2. Volume = area × average depth ÷ 12. Bags = volume × (1 + allowance) ÷ yield per bag. Coverage at 1/4 in = yield ÷ (0.25 ÷ 12).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_septic_tank_sizeMinimum septic tank size, pump tank size and drainfield area for a single-family home under Florida Rule 62-6.008, from bedrooms, building area and soil type.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Minimum septic tank size, pump tank size and drainfield area for a single-family home under Florida Rule 62-6.008, from bedrooms, building area and soil type. Formula: Design flow = the larger of the bedroom flow (100 gpd per bedroom up to 4, then +60 per bedroom) and the building-area flow (100 gpd to 750 sq ft, 200 to 1,200, 300 to 2,250, 400 to 3,300, then +60 per extra 750 sq ft or fraction), per Table I and its footnote 4. Septic tank and pump tank minimums come from Table II for that flow. Drainfield area = max(flow, 200 gpd) ÷ the Table III loading rate for the soil and trench or bed.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_sodSquare feet of sod, number of pieces and pallets for a lawn area.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Square feet of sod, number of pieces and pallets for a lawn area. Piece size and pallet coverage are editable because they vary by farm and grass type. Formula: Sq ft to buy = L × W × (1 + waste%); pieces = sq ft ÷ (piece length × width ÷ 144); pallets = sq ft ÷ pallet coverage.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_solar_panelPanels needed to offset annual electricity use, from panel wattage, peak sun hours and system losses.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Panels needed to offset annual electricity use, from panel wattage, peak sun hours and system losses. Formula: Annual kWh per panel = W/1000 × peak sun hours × 365 × (1 − losses). Panels = ⌈annual use ÷ kWh per panel⌉.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_stair_stringerNumber of risers and treads, exact riser height, total run and stringer length from the floor-to-floor rise, checked against the IRC 7¾ in maximum riser.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Number of risers and treads, exact riser height, total run and stringer length from the floor-to-floor rise, checked against the IRC 7¾ in maximum riser. Formula: Risers = ⌈total rise ÷ max riser⌉; riser height = total rise ÷ risers; treads = risers − 1; total run = treads × tread depth; stringer length = √(rise² + run²).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_stuccoHow many 80 lb bags of stucco you need for a wall: base coat (scratch and brown) bags from the manufacturer's coverage at your system thickness, plus finish coat bags.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How many 80 lb bags of stucco you need for a wall: base coat (scratch and brown) bags from the manufacturer's coverage at your system thickness, plus finish coat bags. Formula: Area = (wall − openings) × (1 + waste). Base bags = area ÷ coverage, where coverage per 80 lb bag = 20–24 sq ft × (3/8 in ÷ base thickness). Finish bags = area ÷ (70 sq ft × 1/8 in ÷ finish thickness).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_tankless_water_heater_sizeSize a tankless water heater from your peak hot-water flow and the rise from winter inlet temperature to your setpoint: required Btu/h, gas input, electric kW and amps.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Size a tankless water heater from your peak hot-water flow and the rise from winter inlet temperature to your setpoint: required Btu/h, gas input, electric kW and amps. Formula: Temperature rise = setpoint − inlet. Heat output (Btu/h) = gpm × 8.34 lb/gal × 60 min × rise. Gas input = output ÷ efficiency. Electric kW = output ÷ 3,412.14; amps = kW × 1,000 ÷ volts.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_thinsetHow many bags of thin-set mortar to buy for your tile area and trowel notch, from manufacturer coverage per 50 lb bag, with a conservative and a best-case count.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How many bags of thin-set mortar to buy for your tile area and trowel notch, from manufacturer coverage per 50 lb bag, with a conservative and a best-case count. Formula: Bags = area × (1 + allowance) ÷ coverage per bag, rounded up, at the low and high ends of the coverage range. Data-sheet coverage per 50 lb bag: 1/4 × 1/4 in 80–95 sq ft, 1/4 × 3/8 in 60–70, 1/2 × 1/2 in 35–40 (scaled for other bag sizes).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_wall_studStuds at 16 or 24 in on center for a wall length, plus extras for corners and openings, and linear feet of top and bottom plate.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Studs at 16 or 24 in on center for a wall length, plus extras for corners and openings, and linear feet of top and bottom plate. Formula: Studs on layout = ⌈length(in) ÷ spacing⌉ + 1; total = layout + corners × extras per corner + openings × extras per opening. Plate linear ft = length × plates.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_water_softener_sizeHow big a water softener you need: grains of hardness removed per day from your household size and water hardness, the grain capacity for your regeneration interval, and how often …No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it How big a water softener you need: grains of hardness removed per day from your household size and water hardness, the grain capacity for your regeneration interval, and how often a given softener will regenerate. Formula: Grains per day = people × gallons per person per day × hardness (gpg). Capacity needed = grains per day × days between regenerations. Days between regenerations = rated capacity ÷ grains per day. gpg = mg/L ÷ 17.1.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_well_pressure_tank_sizeWhat size well pressure tank you need: the drawdown for your pump's flow and minimum run time, the minimum total tank volume at your pressure-switch setting, and the smallest Amtro…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it What size well pressure tank you need: the drawdown for your pump's flow and minimum run time, the minimum total tank volume at your pressure-switch setting, and the smallest Amtrol Well-X-Trol model that delivers it. Formula: Required drawdown = pump gpm × run minutes. Acceptance factor = (cut-out − cut-in) ÷ (cut-out + 14.7). Minimum total tank volume = drawdown ÷ acceptance factor. A tank's drawdown = volume × acceptance factor (capped at its maximum acceptance factor). Run time = drawdown ÷ gpm.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
calc_wire_sizeWhat gauge wire you need for a circuit: copper or aluminum size from the NEC ampacity table at the right temperature column, with the 125% continuous-load rule, the small-conductor…No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it What gauge wire you need for a circuit: copper or aluminum size from the NEC ampacity table at the right temperature column, with the 125% continuous-load rule, the small-conductor breaker limits and an optional voltage-drop check for long runs. Formula: Design amps = load × 1.25 if continuous. Size = smallest AWG whose ampacity in the 60 °C (or 75 °C) column, capped by 240.4(D) for 14/12/10 AWG, is at least the design amps. Voltage drop % = 2 × K × I × L ÷ cmil ÷ V × 100 (√3 for three phase; K = 12.9 copper, 21.2 aluminum); step up until within the limit.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
offer_customlabCustomLab.ai AI operations automation offer from pack JSON.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it CustomLab.ai AI operations automation offer from pack JSON. No price, SKU or Payment Link; CTA is a free 30-minute fit call.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
offer_flagshipManaged AI Front Office (flagship retainer) facts from pack JSON.No findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
Description, as the server wrote it Managed AI Front Office (flagship retainer) facts from pack JSON. HUMAN-GATED: recommend -> human Accept -> written scope -> pay. Agents must not purchase unsupervised.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
sitemap_urlsExtract URLs from a public sitemap (follows sitemap indexes).Reads text others writeCan send data outNo findings
Why it is in this group
- Nothing in its name or description says what it does, so it is counted as a write.
- The server marks it read-only (readOnlyHint: true), but an annotation never lowers a class.
What it can reach
- untrusted-inputThe server marks it openWorldHint: true: it reaches things outside the server's own data.
- outboundThe input takes a URL (input.url): a request to a URL can carry data to whoever runs it.
Description, as the server wrote it Extract URLs from a public sitemap (follows sitemap indexes).
Annotations the server declares
- readOnlyHint: true
- openWorldHint: true
Only reads 3Show 3 read-only tools
federal_awardsSearch federal contract and grant awards from the official USAspending.gov API by keyword, NAICS, state, date and amount.Reads text others writeNo findings
Why it is in this group
- The description's first verb is "search": a word for reading.
What it can reach
- untrusted-inputThe server marks it openWorldHint: true: it reaches things outside the server's own data.
Description, as the server wrote it Search federal contract and grant awards from the official USAspending.gov API by keyword, NAICS, state, date and amount.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: true
fl_contractor_licensesSearch Florida DBPR contractor licenses (official public extract files) by county, trade and issue date.Reads private dataReads text others writeNo findings
Why it is in this group
- The description's first verb is "search": a word for reading.
What it can reach
- private-dataThe description's first sentence says "search" and "file": it reads files.
- untrusted-inputThe server marks it openWorldHint: true: it reaches things outside the server's own data.
- untrusted-inputThe description's first sentence says "search" and "issue": it reads issues, which other people can write.
Description, as the server wrote it Search Florida DBPR contractor licenses (official public extract files) by county, trade and issue date. Business records only.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: true
offer_listList offers in the agent GEO pack (ids + names + status).No findings
Why it is in this group
- The name "offer_list" says "list": a word for reading.
Description, as the server wrote it List offers in the agent GEO pack (ids + names + status). Read-only.
Annotations the server declares
- readOnlyHint: true
- openWorldHint: false
This is not a safety rating, and no finding is not a safety guarantee. The groups and findings come from fixed checks of the tool definitions the server returned on the date shown, not from its code or what it does when called. How the checks work.
Exfil surface
Which tools read private data, which read text someone else can write, and which can send data out. One of each is a path a prompt injection can use.
36 paths in this server alone from private data, through text someone else wrote, to a way out. Denying 1 private-data tool breaks every one.
- Reads private data1
- Reads files, mail, messages, databases, secrets, calendars or repositories.
- Reads text others write6
- Brings in text someone else can write: web pages, inbound email, messages, issues and comments.
- Can send data out6
- Can carry data to people or systems: it sends, posts or publishes, or takes a recipient, channel or URL.
{
"permissions": {
"deny": [
"mcp__provenplaza-agent__fl_contractor_licenses"
]
}
}Other servers in the same agent add their own tools to these paths. Audit your whole setup to see them together.
Remote posture
What anyone on the internet sees at the remote endpoint: an anonymous initialize and tools/list, and the public OAuth metadata.
Looked at Nov 20, 2026, 19:01 UTC, unchanged since Nov 6, 2026. No credentials were sent and no tool was called. What is looked at.
- Reachable
- yes
- HTTP status of an anonymous initialize
- 200
- tools/list served without credentials
- yes
- Tools that change things, listed without credentials
- 69
- Protocol version
- 2025-06-18
- WWW-Authenticate on 401
- not observed
- resource_metadata in WWW-Authenticate
- not observed
- RFC 9728 protected resource metadata
- not observed
- Authorization servers
- not observed
- Legacy HTTP+SSE transport
- no
- Dynamic client registration
- not observed
- Client ID metadata documents
- not observed
- HighThe whole server
The endpoint served tools/list without credentials, and the list has 69 tools that change things (1 destructive, 1 irreversible, 67 write). Whether a call also works without credentials was not tested: tools are never called.
What this check looks forMatched text
https://provenplaza-agent-mcp.zvorsteg1.workers.dev/mcp: tools/list returned 72 tools to an anonymous client, including calc_voltage_drop (destructive), sofl_permits (irreversible), calc_concrete_slab (write), calc_concrete_column (write), calc_concrete_footing (write) and 64 more
Posture changes
- Nov 6, 2026
- Tools that change things, listed without credentials: 63 to 69
- Oct 29, 2026
- Tools that change things, listed without credentials: 47 to 63
Findings
Matches of fixed checks, with the text they matched.
The server marks "calc_voltage_drop" read-only (readOnlyHint: true), and its own name, description or input give the class "destructive".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The name "calc_voltage_drop" says "drop": a word for removing or ending something.
- Warncalc_fence
The server marks "calc_fence" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The description's first verb is "post": a word for a change.
- Warncalc_box_fill
The server marks "calc_box_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The name "calc_box_fill" says "fill": a word for a change.
The server marks "calc_conduit_fill" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The name "calc_conduit_fill" says "fill": a word for a change.
- Warnsofl_permits
The server marks "sofl_permits" read-only (readOnlyHint: true), and its own name, description or input give the class "irreversible".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":true}; The input addresses people (input.to): what it sends cannot be taken back.
The server marks "agent_ready_fix_pack" read-only (readOnlyHint: true), and its own name, description or input give the class "write".
What this check looks forMatched text
annotations: {"readOnlyHint":true,"openWorldHint":false}; The description's first verb is "generate": a word for a change.
History
Changes to its tool definitions and to its remote endpoint, newest first.
PostureRemote posture changed. Tools that change things, listed without credentials: 63 -> 69.View diff
- Tools that change things, listed without credentials: 63 to 69
Tools22 added, 1 changed.+22 added~1 changedView diff
- Added:calc_box_fillChanges things
- Added:calc_caulkChanges things
- Added:calc_ceiling_fan_sizeChanges things
- Added:calc_conduit_fillChanges things
- Added:calc_dehumidifier_sizeChanges things
- Added:calc_epoxy_floorChanges things
- Added:calc_ev_charging_costChanges things
- Added:calc_grass_seedChanges things
- Added:calc_joint_compoundChanges things
- Added:calc_lawn_fertilizerChanges things
- Added:calc_mortarChanges things
- Added:calc_pool_heater_sizeChanges things
- Added:calc_pool_lsiChanges things
- Added:calc_pool_turnoverChanges things
- Added:calc_rainwater_harvestingChanges things
- Added:calc_self_leveling_concreteChanges things
- Added:calc_stuccoChanges things
- Added:calc_tankless_water_heater_sizeChanges things
- Added:calc_thinsetChanges things
- Added:calc_water_softener_sizeChanges things
- Added:calc_well_pressure_tank_sizeChanges things
- Added:calc_wire_sizeChanges things
- Changed:calc_pool_volumeChanges thingstitle
PostureRemote posture changed. Tools that change things, listed without credentials: 47 -> 63.View diff
- Tools that change things, listed without credentials: 47 to 63
Install
Pinned to version 0.1.2. Values in angle brackets are yours to fill in.
claude mcp add --transport http provenplaza-agent https://provenplaza-agent-mcp.zvorsteg1.workers.dev/mcpclaude mcp add --transport http provenplaza-agent https://provenplaza-agent-mcp.zvorsteg1.workers.dev/mcpRun in a terminal.
Claude Code permissions
Allow the reads, ask before a change or a way out, deny the deletes. Paste into .claude/settings.json.
{
"permissions": {
"allow": [
"mcp__provenplaza-agent__fl_contractor_licenses",
"mcp__provenplaza-agent__federal_awards",
"mcp__provenplaza-agent__offer_list"
],
"ask": [
"mcp__provenplaza-agent__calc_concrete_slab",
"mcp__provenplaza-agent__calc_concrete_column",
"mcp__provenplaza-agent__calc_concrete_footing",
"mcp__provenplaza-agent__calc_paint",
"mcp__provenplaza-agent__calc_roofing",
"mcp__provenplaza-agent__calc_drywall",
"mcp__provenplaza-agent__calc_flooring_tile",
"mcp__provenplaza-agent__calc_mulch_gravel",
"mcp__provenplaza-agent__calc_ac_btu",
"mcp__provenplaza-agent__calc_deck_board",
"mcp__provenplaza-agent__calc_fence",
"mcp__provenplaza-agent__calc_insulation_r_value",
"mcp__provenplaza-agent__calc_pool_volume",
"mcp__provenplaza-agent__calc_round_pool_volume",
"mcp__provenplaza-agent__calc_oval_pool_volume",
"mcp__provenplaza-agent__calc_solar_panel",
"mcp__provenplaza-agent__calc_board_foot",
"mcp__provenplaza-agent__calc_asphalt",
"mcp__provenplaza-agent__calc_stair_stringer",
"mcp__provenplaza-agent__calc_rafter_length",
"mcp__provenplaza-agent__calc_wall_stud",
"mcp__provenplaza-agent__calc_brick",
"mcp__provenplaza-agent__calc_concrete_block",
"mcp__provenplaza-agent__calc_paver",
"mcp__provenplaza-agent__calc_sod",
"mcp__provenplaza-agent__calc_pool_salt",
"mcp__provenplaza-agent__calc_pool_chlorine",
"mcp__provenplaza-agent__calc_generator_size",
"mcp__provenplaza-agent__calc_rebar",
"mcp__provenplaza-agent__calc_retaining_wall",
"mcp__provenplaza-agent__calc_appliance_energy_cost",
"mcp__provenplaza-agent__calc_gutter_size",
"mcp__provenplaza-agent__calc_concrete_steps",
"mcp__provenplaza-agent__calc_grout",
"mcp__provenplaza-agent__calc_attic_ventilation",
"mcp__provenplaza-agent__calc_septic_tank_size",
"mcp__provenplaza-agent__calc_pool_alkalinity",
"mcp__provenplaza-agent__calc_pool_stabilizer",
"mcp__provenplaza-agent__calc_pool_calcium_hardness",
"mcp__provenplaza-agent__calc_pool_lsi",
"mcp__provenplaza-agent__calc_pool_heater_size",
"mcp__provenplaza-agent__calc_pool_turnover",
"mcp__provenplaza-agent__calc_tankless_water_heater_size",
"mcp__provenplaza-agent__calc_box_fill",
"mcp__provenplaza-agent__calc_mortar",
"mcp__provenplaza-agent__calc_thinset",
"mcp__provenplaza-agent__calc_water_softener_size",
"mcp__provenplaza-agent__calc_well_pressure_tank_size",
"mcp__provenplaza-agent__calc_dehumidifier_size",
"mcp__provenplaza-agent__calc_epoxy_floor",
"mcp__provenplaza-agent__calc_conduit_fill",
"mcp__provenplaza-agent__calc_wire_size",
"mcp__provenplaza-agent__calc_stucco",
"mcp__provenplaza-agent__calc_self_leveling_concrete",
"mcp__provenplaza-agent__calc_caulk",
"mcp__provenplaza-agent__calc_ceiling_fan_size",
"mcp__provenplaza-agent__calc_joint_compound",
"mcp__provenplaza-agent__calc_lawn_fertilizer",
"mcp__provenplaza-agent__calc_grass_seed",
"mcp__provenplaza-agent__calc_rainwater_harvesting",
"mcp__provenplaza-agent__calc_ev_charging_cost",
"mcp__provenplaza-agent__ai_crawler_audit",
"mcp__provenplaza-agent__sitemap_urls",
"mcp__provenplaza-agent__sofl_permits",
"mcp__provenplaza-agent__agent_readiness_score",
"mcp__provenplaza-agent__agent_ready_fix_pack",
"mcp__provenplaza-agent__offer_flagship",
"mcp__provenplaza-agent__offer_customlab"
],
"deny": [
"mcp__provenplaza-agent__calc_voltage_drop"
]
}
}Tools that only read are allowed, tools that change things ask first, tools that delete or cancel are denied. A read that can send data out (it takes a URL, say) asks first too. It assumes the server is installed as provenplaza-agent. Review it before you use it.
Capability tags behind 8 rules
- mcp__provenplaza-agent__calc_fence outbound
- mcp__provenplaza-agent__ai_crawler_audit untrusted-input, outbound
- mcp__provenplaza-agent__sitemap_urls untrusted-input, outbound
- mcp__provenplaza-agent__fl_contractor_licenses private-data, untrusted-input
- mcp__provenplaza-agent__sofl_permits untrusted-input, outbound
- mcp__provenplaza-agent__federal_awards untrusted-input
- mcp__provenplaza-agent__agent_readiness_score untrusted-input, outbound
- mcp__provenplaza-agent__agent_ready_fix_pack outbound
Pin
Keep the decision: fail CI when the tools change, follow every change, or show a badge.
Pin in CI
Fail a build when the tools you reviewed are not the tools the server serves today.
curl -s "https://radar.anlyon.com/api/v1/servers/io.github.ZacharyVorsteg/provenplaza-agent-mcp/verify?hash=b8d0671b5170a91b30e748e89f6f4a82f699056d6cb1a21dadfce294936a681a" | jq -e '.changed == false'Pinned hash b8d0671b5170, from Nov 16, 2026, 07:18 UTC.
Watch
Get told when its tools change: a new tool, a new description, a new class.
https://radar.anlyon.com/servers/io.github.ZacharyVorsteg/provenplaza-agent-mcp/changes.xmlAn Atom feed. Works in any feed reader or Slack's RSS app.
Badge
[](https://radar.anlyon.com/servers/io.github.ZacharyVorsteg/provenplaza-agent-mcp)Source: MCP Registry · repository. Synced Oct 21, 2026, 18:22 UTC.
Proven Plaza Calculators & Open Data MCP server: questions and answers
Answered from the scan above, not from the publisher's description.
Is the Proven Plaza Calculators & Open Data MCP server safe?
- No scan can promise that. What its definitions show: 72 tools, 69 of which can change, send or delete something, and 6 findings from fixed checks. Allow the reads, ask before each change, and deny the deletes; the permissions block on this page does that.
Can the Proven Plaza Calculators & Open Data MCP server delete data?
- Yes. 1 tool can delete, cancel or revoke something: calc_voltage_drop.
Can the Proven Plaza Calculators & Open Data MCP server do things that cannot be undone?
- Yes. 1 tool can send, pay, publish or merge: sofl_permits.
What tools does the Proven Plaza Calculators & Open Data MCP server have?
- 72 tools: 1 destructive, 1 irreversible, 67 write, 3 read. calc_voltage_drop, sofl_permits, calc_concrete_slab, calc_concrete_column, calc_concrete_footing, calc_paint, calc_roofing, calc_drywall and 64 more.
Does the Proven Plaza Calculators & Open Data MCP server need sign-in or OAuth?
- Its remote endpoint listed its tools to an anonymous client, without sign-in.
Does the Proven Plaza Calculators & Open Data MCP server send data to outside services?
- 6 tools can carry data out (it sends, posts or publishes, or takes a recipient, channel or URL): calc_fence, ai_crawler_audit, sitemap_urls, sofl_permits, agent_readiness_score and agent_ready_fix_pack.
Has the Proven Plaza Calculators & Open Data MCP server changed its tools?
- Yes, once since Anlyon Radar started tracking it, most recently on Nov 2, 2026. Every change is on this page and in its Atom feed.